Function And Description Setting Range Unit Remarks max speed speed 1 Speed 2 speed 3 trimming after urgentstop 1 Yes, 0 No top needle stop position 4319 check frequency 15~ 45 stretching time 150~ 1000 presser foot put down time 150~ 500 thread trim switch 0 off , 1on...
Page 36
Function And Description Setting Range Unit Remarks x origin -500000------500000 y origin -500000------500000 thread trim open angle 0------355 thread release dev angle 160------320 Clamping solenoids PWM 10------1000 presser plate 1 solenoids pwm 10------1000 presser foot solenoids pwm 10------1000 presser plate 2 solenoids pwm 10------1000 x sensor polarity 0invariant---1negation...
Page 37
Function And Description Setting Range Unit Remarks cutting speed 200-----500 working/testing switch 0working',1testing material receipt motor start time 0-----60 main shaft motor 0off-line 1online testing mode 0machine 1main shaft presser foot up speed 1-----6 presserfoot up when FWD/BWD 0no',1yes Multiples of V and SV 0-----10 machine type 0 9000G---1 3020G...
Page 38
8. Alarm description, possible cause and corrective action The PSDA driver has various protective functions. When one of the protections is activated, the motor trips according to the timing chart, and the Servo Alarm Output (ALM) is turned off. Actions to be taken after trip events •...
Page 39
acceptable range, so that the P-N voltage of voltages (between R, S and T). Remove the converter is larger than the specified the causes. Feed a power of correct value, or the line voltage was raised by a voltage. condensive load or UPS (Uninterruptible Measure the P-B2 resistance of the Power Supply).
Page 40
operates per the position command pulse or not. See the torque monitor to check if the output torque is saturated. Readjust the gains. Maximize the value of Pr12 (torque limit set-up). Correct the encoder wiring per wiring diagram. Increase acceleration deceleration time.
Page 41
Check whether the value of the Pr65 parameter is too small. Detection sequence corresponding to the drive motor definition is correct. Detection sequence corresponding to the drive motor definition is correct. Abnormal motor operating speed. Motor rotation blockage. Speed windage Check motor wiring is correct.