LOCATION AND MOUNTING

**When selecting a location for any Aqua-Lab system make sure to consider the proximity to feed water,
power supply, and the control cabinet that the valve signals will need to be wired from (or a junction box
with the appropriate signals wires) as well as space near the system to store chemical containers.
SPACE REQUIREMENTS:
Aqua-Lab Systems
TXF Model – 3' x 3' footprint with 5' Clearance
TXW Model – 2' wide x 4.5' high of wall space
AX Model – 3' wide x 2' high of wall space
BX Model – 1.5' wide x 2' high of wall space
Pump Assemblies (For TXW, AX, and BX Models) – Pumps need to be within 3' of the system to allow
connection of the two with just the included connection hose
Single Pump – 4' x 1' wall or floor space
Dual Pump Wall mount – 4' x 2.5' of wall space
Dual Pump Floor skid – 4' wide x 1.5' deep footprint with 4' of Clearance
Electrical Enclosures
Motor Starter (TXW, AX, and BX with Wall mount pump assembly) – 1' wide x 1.5' high of wall
space
VFD Motor Controller (TXW, AX, or BX with Wall mount pump assembly) – 1.5' wide x 2' high
of wall space
Terminal Box (Optional Item – used if 30' signal cables do not reach car wash control cabinet)
– 1' wide x 1' high of wall space
MOUNTING OF COMPONENTS:
Aqua-Lab Systems
TXF – Position on the floor in optimal location, can be anchored with included anchor feet
TXW – Mount to concrete or cinder block wall with 4 concrete anchors
AX – Mount to concrete or cinder block wall with 4 concrete anchors
BX – Mount sturdy wall with 4 appropriate anchors
Pump Assemblies – Does not apply to TXF
Single Pump – Mount pump flange to concrete or cinder block wall or concrete floor with 4
concrete anchors – **Needs to be within 3' of the Aqua-Lab system to connect them with the
included connection hose
Dual Pump Wall mount – Mount to concrete or cinder block wall with 4 concrete anchors
– **Needs to be within 3' of the Aqua-Lab system to connect them with the included
connection hose
Dual Pump Floor skid – Position on the floor near the feed water connection – **Needs to be
within 3' of the Aqua-Lab system to connect them with the included connection hose
Electrical Enclosures
Motor Starter – (Pre mounted to the Frame for TXF) for other systems mount to the wall with
4 appropriate anchors
VFD Motor Controller – (Pre mounted to the Frame for TXF) for other systems mount to the
wall with 4 appropriate anchors
Terminal Box (Accessory) – Mount to wall with 4 appropriate anchors – **Location will depend
on the position of the Aqua-Lab system and its proximity to the car wash control cabinet