  • Page 1 i-Q350 RCM SensorSMART™ Installation and Operation Manual VISIBILITY DELIVERED.
  • Page 2 IDENTEC SOLUTIONS shall not under any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages.
  • Page 3 The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or unauthorized changes to approved products, may void the compliance of these products and may result in the loss of the user(s) authority to operate the equipment.
  • Page 4 i-Q350 RCM USER MANUAL This product contains components that are sensitive to electrostatic discharges. Please observe the special instructions for their protection. Incorrect handling can damage the unit and cause the invalidation of the warranty. Minimum safety precautions against electrostatic discharge: •...
  • Page 5: Table Of Contents

    i-Q350 RCM USER MANUAL Contents     SAFETY INSTRUCTIONS ....................6 1.1.   ......................7   REPARATIONS     1.2....................7 COPE OF OCUMENT     1.3......................8 ESPONSIBILITY     1.4........................8 PDATES     1.5. —V ................
  • Page 6: Safety Instructions

    i-Q350 RCM USER MANUAL 1. SAFETY INSTRUCTIONS The system described in this manual is for exclusive operation of trained employees. Only qualified personnel that have knowledge of the potential dangers involved should perform the installation, settings, maintenance and repair of the units used. Operational Safety The correct and safe use of these systems assumes that operating and service personnel follow the safety measures described in the manual alongside the generally acceptable safety procedures.
  • Page 7: Preparations

    If it is necessary to check the isolating properties of the field wiring, the assemblies (electronic units and sensors) should be disconnected. Earth the test units. IDENTEC SOLUTIONS does not accept the return of products where the regulations concerning the ESD precautions and protective packaging materials were not followed. ESD – Electrostatic Discharge EMC –...
  • Page 8: Responsibility

    USER MANUAL 1.3. Responsibility IDENTEC SOLUTIONS reserves the right to make changes and updates to the content contained herein. It is the user’s responsibility to contact the service department for any possible changes or updates to operating and maintenance procedures.
  • Page 9: Introduction

    2. INTRODUCTION 2.1. Fundamentals The IDENTEC SOLUTIONS’ SensorSMART Platform is the latest development in asset management, localization and process optimization. Developed to deliver the last mile in industrial communication, the SensorSMART Platform fulfills a niche not previously addressed by available networks.
  • Page 10: Introduction

    Designed to automate the data collection and business processes associated with refrigerated container management in complex marine and intermodal terminal environments, the Reefer Container Monitoring System (RCMS) from IDENTEC SOLUTIONS represents the next generation in ‘plug and play’ wireless reefer monitoring and control.
  • Page 11 i-Q350 RCM USER MANUAL 3.2.2. Polarization of Sensors Vertically Polarized Horizontally Polarized Polarization is dependent on orientation and is rotation symmetrical. VISIBILITY DELIVERED. PAGE 11 OF 28...
  • Page 12: System Components-Readers

    3.4. System Components—Antennas IDENTEC SOLUTIONS’ antennas are distinguished by their compact design. A variety of antennas can be used, depending on application. The antennas are differentiated by characteristics such as polarization, apex angle, and gain.
  • Page 13 i-Q350 RCM USER MANUAL Orientation Diagrams: Elliptical polarized antenna Elevation Azimuth For this antenna, the maximum transmit power setting is: • A-9185: -8 dBm 3.4.2. Linear Polarized Antennas Because of the smaller apex angle (60º), this antenna is more suited to selective data collection and restriction of read zones.
  • Page 14 i-Q350 RCM USER MANUAL Orientation Diagrams: Linear polarized antenna Elevation Azimuth Vertical Polarization Horizontal Polarization Antenna Orientation For this antenna, the maximum transmit power setting is: • W-900R: -12 dBm VISIBILITY DELIVERED. PAGE 14 OF 28...
  • Page 15 i-Q350 RCM USER MANUAL 3.4.3. 1-Wave Rod Antenna Overall Dimensions: 425 × 90 mm Mounting proposal Antenna diagram Vertical For this antenna, the maximum transmit power setting is: • Rod antenna: 6 dBm VISIBILITY DELIVERED. PAGE 15 OF 28...
  • Page 16: Tag Mounting Solutions

    i-Q350 RCM USER MANUAL 4. TAG MOUNTING SOLUTIONS The Tag can be mounted either with cable straps using the 2 slits at each end, by using screws or a magnet as described in the following 3 subchapters. 4.1. Cable Straps 4.2.
  • Page 17 i-Q350 RCM USER MANUAL Important Information 1. Only screws with cylindrical heads are suitable for mounting the tag. We do not advise using counter- sunk screws. If for some reason this should be necessary, then use only with a suitable counter-sunk cushioning disc (refer to UN 1277).
  • Page 18: Magnet (Optional)

    i-Q350 RCM USER MANUAL 4.3. Magnet (optional) The tag can be easily removed by grabbing it on the part of its body with the cable outlet. Slightly pull it off the wall and the magnetic holding force is removed at once. DO NOT pull the cable.
  • Page 19: Connecting To The Reefer Controller

    i-Q350 RCM USER MANUAL 5. CONNECTING TO THE REEFER CONTROLLER Safety Instructions A screened cable must be used for the data cable. Important Note The total cable runs between tag and the monitored device must not exceed a total of 15 m. This is due to limitations of the RS232 (EIA-232) standard.
  • Page 20 i-Q350 RCM USER MANUAL Step 3 Align the bayonet locking mechanism by rotating the outer ring on the male connector. Step 4 Press both connector together and lock the bayonet mechanism to insure proper electrical connection and weatherproofness. VISIBILITY DELIVERED. PAGE 20 OF 28...
  • Page 21: Accessories

    i-Q350 RCM USER MANUAL 6. ACCESSORIES In order to accomodate different installations and to operate with most of the reefer container's plug's variation, we are providing several accessories. 6.1. Extension Cable We are providing a 2 meters (6 ft) extension cable to accomodate installation where the i-Q350 RCM is installed on racks.
  • Page 22: Adaptors

    i-Q350 RCM USER MANUAL 6.2. Adaptors Multiple adaptors are available in order to connect the i-Q350 RCM to different type of reefer controllers. Each adaptor is 50 centimeters (19 inches) long and use the standard 5 pin Deustch female connector to connect to the tag.
  • Page 23: Connecting To The Tag

    i-Q350 RCM USER MANUAL 6.3. Connecting to the tag Follow the process hereafter to connect the extension cable or adaptors to the i-Q350 RCM. Step 1 Align the male connector of the i-Q350 RCM tag to the female connector of the adaptor or extension cable.
  • Page 24 i-Q350 RCM USER MANUAL Step 4 Press both connector together and lock the bayonet mechanism to insure proper electrical connection and weatherproofness. VISIBILITY DELIVERED. PAGE 24 OF 28...
  • Page 25: Troubleshooting

    i-Q350 RCM USER MANUAL 7. TROUBLESHOOTING 7.1. General This chapter covers how faults can be recognized and rectified. There are potentially four main problem sources: • The user control system, including task requirements, communication cables, peripheral units with possible object recognition switches. •...
  • Page 26: Maintenance

    Parts or main components returned for repair or exchange must be handled with great care. PC cards must be returned in the appropriate ESD-protecting packaging material. All returns should include an error description and a short application overview and be sent to the local distributor or to: IDENTEC SOLUTIONS AG Service Department Millenium Park 2...
  • Page 27: Technical Data

    i-Q350 RCM USER MANUAL 9. TECHNICAL DATA Communication Broadcast 350 Operation Mode Transmits Sensor ID and user data in pre-defined interval Read Range up to 500m* Compatibility i-PORT M350, i-CARD CF 350 and i-PORT 4-350 Operating Frequency 868 MHz (EU) or 920 MHz (NA) Transmit Power <1mW Communication Response 350...
  • Page 28 i-Q350 RCM USER MANUAL Environmental Conditions Operating Temperature –20 °C to +70 °C (–4 °F to +158 °F) Humidity 10% to 95% relative humidity @ 30°C Shock Multiple drops to concrete from 1m (3ft), 3 times DIN IEC 68-2- Vibrations 3G, 20 sine wave cycles, 5 to 150 Hz, DIN IEC 68-2-6 5G, noise 5 to 1.000 Hz, 30 minutes, DIN IEC 68-2-64 Standard/Certification...