The angles are determined for the horizontal or x axis and the vertical or y axis with respect to the z axis
which is normal to the LCD module surface.
Ø =180°,Left
9.5.2.4. Test Signal
(1) Input signal : Standard preset timing (3,840 x 2,160(30Hz) or 1920 X 1080 (60Hz))
(2) Pattern: Red, Green, Blue, White, Black, 60/255 Gray, 127 / 255 Gray pattern.
9.5.3 Inspection Criteria
9.5.3.1 Dot Defect
(1) Bright Dot
Dot (sub-pixels) which appeared brightly in the screen shen the LCM displayed with dark
pattern.
R,G or B 1 dot
Adjacent2 dots
Adjacent3 dots
Total amount of Bright dots
(2) Partial Bright Dot
Among Bright dots, the size of Dots(sub-pixels) which appeared less than half size
of sub-pixel is defined as partial bright dot.
Inspection Pattern
(3) Dark Dot
Dots (sub-pixels)which appeared darkly in the screen when the LCM
displayed with bright pattern.
Adjacent2 dots
Adjacent3 dots
Min. distance
Between dark dots
Total amount of Dark dots
REV 0.1
Normal
E
θ
ø
Ø =270°,Down
Item
Q'ty
Item
1 dot
Y
Ø =90°,Up
Right (Ø =0°)
Left (Ø =180°)
Ø =0°,Right
Up (Ø =90°)
Down (Ø =270°)
FIG. Viewing Angle
Max 4
Max 1
Max 4
Max 30
Max 15
Max 6
Max 2
Min 20mm
Max 15
Service Manual
Θ (x axis) = 89°
Θ (x axis) = 89°
Θ (y axis) = 89°
Θ (y axis) = 89°
84"
0
84"
84"
60