EXTERIOR DIMENSIONS

UTILITY SPECIFICATION

Model #
1961
1962
1962-000-E
1963-000-E
1964-000-E
1964
COMPONENTS
4" LEG
ANGLE PLUG – 50 AMP, 250 VAC, 3 PHASE
(Domestic units only)
(Wire & Plug not included with CE units)
4
Input Rate
Voltage
12 kW
208V
12 kW
240V
11.5kW
415/240V
11.5kW
400/230V
11.5kW
380/220V
11.5kW
220V
Amps
Phase
36
3
32
3
34.5
3
36
3
37.5
3
37.5
3
REQUIRED CLEARANCE
The unit must have 6 inches (152 mm) of
clearance from combustible surfaces. In case
other equipment is located on the right side of
the unit, a minimum clearance of 24 inches
(610 mm) is required from that equipment.
FOR ALL UNITS: A 24-inch (610-mm)
clearance at the rear of the unit must be
obtainable for service access.
DTF – 1960 Series Operator Manual
HZ
60
60
50
50
50
50