Universal Power Supply (UPS)
6.1

Power-up and test for proper function

Turn on power after the light curtain has been correctly
installed in conjunction with the Universal Power Supply.
The start-up time for the UPS takes max. 4 s.
The green LED in the Universal Power Supply indicates
that there is supply voltage available.
An orange LED indicates the status of the light curtain
and the output relay.
Installation tip:
When the buzzer is switched on with the sliding switch, a disrupted beam condition is indicated with a buzzer signal. This
function is very helpful after installation to check the proper function of the UPS as well as of the connected light curtain.
If the UPS or the light curtain do not operate as described in this section, please refer to chapter 7 "Trouble shooting".

7. Trouble shooting

Fault / Problem
Action
Door remains
Is the power supply OK?
 Measure the main power on the connector. The main power must be 20 ... 265 VAC or
open; green and
orange LED OFF
 Check the power LED (green) on the UPS.
Is any wire broken?
 Measure and check the main power cables.
Door remains
Is the light curtain correctly connected to the UPS?
 Make sure that the emitter and receiver cables are connected to the UPS.
open; protective
Is the grounding (PE) connection faulty?
area is free
 Make sure that the grounding (PE) is connected to the UPS.
Are the sensors looking "face-to-face"?
 It is important that the active parts of the emitter and receiver units are mounted so that they
Are the sensors or vision shields dirty?
 The active sensor part is the side with the black round lenses. Make sure that the black lenses
 Make sure that the vision shields are not painted or scratched.
Is any beam interrupted?
 Make sure that no object blocks the light path between emitter and receiver while the door
Are the edges incorrectly aligned?
 The optical axis of the emitter (Tx) and the receiver edge (Rx) need to be aligned towards
Is there excessive EMC interference e.g. from door drive?
 Do not guide the connection cables of the light curtains close to cables carrying high voltage
Is there excessive light interference e.g. from fluorescent lamps?
 Do not install the receiver edges of the light curtain directly exposed to light sources such as
Random door
Is either the emitter or receiver cable damaged?
 Check for breaks in the cables by feeling the cables by hand.
openings
Is there any interference with the emitter from other infrared sensors (either directly or via
mirroring from shiny surfaces)?
 Avoid interference from blinking lights or infrared light sources such as photo cells or other
 Reflective surfaces near or parallel to the safeguarded area can cause reflections.
If a problem persists, please contact your local CEDES representative. Visit www.cedes.com for contact data.
6
20 ... 375 VDC.
face each other. The active sensor part is the side with the black round lenses.
are clean and not painted or scratched.
is open and while the door is closing.
each other to ensure the light curtain functions reliably.
and/or high current. The cables should also be mounted as far away as possible from the
door drive motor or motor inverter (VVVF-drives) to avoid EMI problems.
FL tubes or energy-saving lamps.
light curtains.
Orange LED
Light curtain
ON
Obstruction
OFF
No obstruction
English
Output relay
COM = NC
COM = NO
© CEDES | V 1.0