Caution For Wiring - Denso SMT7 Instruction Manual

Densorobot
Table of Contents

Advertisement

5.2.4

Caution for Wiring

The figure below shows the wiring example when a motor is connected to the SMT7.
Absolute value encoder transmits data in serial communication. So, securely connect
shield or F.G.
(1) Secure the FG terminal of the encoder branch cable to the original screw on the
(2) Lay the wiring away from the noise occurrence source.
(3) Do not bind encoder cable and motor cable together.
(4) When disconnecting the motor cable connector from the motor branch cable, pull
Caution: Do not bundle the teach pendant cables, I/O cables or motor cables together with high
power lines such as 200 VAC lines and peripheral device cables, or route the motor cables
near high power devices (motor, welder, parts feeder, etc.).
Chapter 5 Installation and Wiring
controller.
the connector while pushing the connector lock.
Wiring example when a motor is connected to the SMT7
97