  • Page 1 20000003996d EUROSTAR_102017 EUROSTAR 200 control ® EUROSTAR 200 P4 control ® Operating instructions...
  • Page 2 EUROSTAR Wireless Controller station (WiCo) Fig. 2 Fig. 1 Fig. 3 Fig. 4 RS 232 Temp. Sensor Fig. 5 Fig. 6 Fig. 7 Fig. 8...
  • Page 3: Table Of Contents

    Drive Error codes Motor protection Warranty Speed – normal operation Accessories Speed – overload operation Permitted IKA ® stirrer tools Output shaft Technical data Speed display Declaration of Conformity We declare under our sole responsibility that this product corresponds to the regulations 2014/35/EU, 2006/42/EC, 2014/30/EU and 2011/65/EU and conforms with the standards or standardized documents EN 61010-1, EN 61010-2-051, EN 61326-1, EN 60529 und EN ISO 12100.
  • Page 4: Explication Of Warning Symbols

    • Socket must be earthed (protective ground contact). precautions (e.g. shatter protection). In any case, when using • The voltage stated on the type plate must correspond to the mains critical or hazardous materials in your processes, IKA ® recom- voltage.
  • Page 5 Disposal instructions: • If the instrument is operated too long in overload or if the ambi- • When disposing of the IKA battery pack, please tape over the ® ent temperature is too high, the instrument switches off per- contacts with adhesive tape to prevent short-circuiting due to manently.
  • Page 6: Correct Use

    - In the case of any damage a detailed report must be sent im- mediately (post, rail or forwarder). • Delivery scope: Adapter Adapter - EUROSTAR 200 control or EUROSTAR 200 P4 control Europe, Switzerland USA, China stirrer with a Wireless Controller (WiCo) of the type ordered - An operating instructions...
  • Page 7: Speed - Overload Operation

    Message in the display: Error 4 (see “Error codes” section). Output shaft The clamping chuck and output shaft permit clamping IKA recom- ® For safety reason, the stirrer cover must be pushed back into the mend stirrer tools (see section “Permitted IKA...
  • Page 8: Switching On The Instrument

    - Install the driver automatically, if it is not already installed - Prompt the user to perform a manual installation Securing the stirring shaft protector Open http://www.ika.com/ika/lws/download/usb-driver.zip Diagram (see Fig. 5) Charging the RB 1 battery pack (rechargeable battery) Use a stirring shaft protector (Q), e.g.
  • Page 9: Useful Information

    If the Bluetooth ® function of the Wireless Controller is active, the The stirrer has two different speed ranges: user can use the Bluetooth search button (H) to search for the Range I: low speed, high torque. ® Wireless Controller. A beep signal will be audible even if the Wire- Range II: high speed, low torque.
  • Page 10 LIMIT Speed limit: USB: This symbol indicates upper speed limit set for the stirrer. The setting This symbol means the EUROSTAR station is communicating via of the EUROSTAR in delivery status is the maximum permissible a USB cable. speed of the stirrer. The symbol no longer appears if no USB cable is being used for communicating with the station.
  • Page 11 Menu structure Factory settings Stirring Speed Limit ………………………………………………………………………… 2000 rpm EUROSTAR 200 control 530 rpm EUROSTAR 200 P4 control Torque Limit ……………………………………………………………..………… 200 Ncm EUROSTAR 200 control 660 Ncm EUROSTAR 200 P4 control Torque Display ……………………………………………………………………… activated Intermittent Mode Run/Stop …………………………………..- Interval Run Time…..…………...
  • Page 12 Menu (details): Stirring: Speed Limit: Torque Display: The ”Speed Limit” menu allows the user to set the desired maxi- The ”Torque Display” menu allows the user to specify that the mum upper speed limit for the EUROSTAR 200 / 200 P4 control torque is shown in the display.
  • Page 13 Temperature: Programs: In the ”Temperature” menu the user can specify that the tem- Under menu "Programs", 5 user-defined speed (rpm)-time pro- perature sensor is displayed on the display/working screen. A tick files can be created. In addition, the user could define the intermit- shows that the option is activated.
  • Page 14 View the program in graph: After a program is being edited, press the "Back" button to save the settings. Press the "Back" button again, the screen back to follow screen. Programs Program 1 Program 2 Program 3 Program 4 Program 5 Start Edit Delete...
  • Page 15 Sample for editing the program: PROGRAM 1 PROGRAM 1 Programs Programs Programs Time Interm. Time Interm. hh:mm Mode hh:mm Mode Program 1 Program 1 Program 1 00:00 00:00 Program 2 Program 2 Program 2 Program 3 Program 3 Program 3 Program 4 Program 4 Program 4...
  • Page 16 Settings: Safety: Languages: Time Out: The “Languages“ option allows the user to select the desired In the “Time Out“ menu, the user can set a time limit. This time language by turning and pressing the rotary/push knob (B). A tick limit applies if there is a communication failure between the indicates the language that is set for the system.
  • Page 17: Interfaces And Outputs

    PC. With a suitable terminal http://www.ika.com/ika/lws/download/usb-driver.zip. or communications programme these commands can be transmit- Install the driver by running the setup file. Then connect the IKA ® ted directly to the stirrer equipment. The IKA ®...
  • Page 18: Maintenance And Cleaning

    For cleaning disconnect the main plug! When ordering spare parts, please give: - machine type - manufacturing number, see type plate Use only cleaning agents which have been approved by IKA ® - item and designation of the spare part see www.ika.com, clean IKA ®...
  • Page 19: Error Codes

    - Contact the service department - Send the instrument for repair, including a short description of the fault. Warranty In accordance with IKA ® warranty conditions, the warranty period The warranty does not cover worn out parts, nor does it apply is 24 months.
  • Page 20: Technical Data

    Technical data EUROSTAR 200 control EUROSTAR 200 P4 control EUROSTAR station + Wireless Controller (WiCo) Speed range I (high torque) 0 / 6 – 400 0 / 4 – 110 Speed range II (high speed) 0 / 30 – 2000 0 / 16–...
  • Page 21 -Werke GmbH & Co.KG ® Janke & Kunkel-Str. 10 D-79219 Staufen Tel. +49 7633 831-0 Fax +49 7633 831-98 sales@ika.de www.ika.com...