Daikin WinterSpa RHR-C Series Technical Manual
Daikin WinterSpa RHR-C Series Technical Manual

Daikin WinterSpa RHR-C Series Technical Manual

Heat reclaim

Advertisement

Quick Links

Heat Reclaim
TECH NI CAL MANUAL
TM-RHR-1214-A

Advertisement

Table of Contents
loading

Summary of Contents for Daikin WinterSpa RHR-C Series

  • Page 1 Heat Reclaim TECH NI CAL MANUAL TM-RHR-1214-A...
  • Page 2: Table Of Contents

    Table of Contents 1. Model Name ......................1 2. Features ........................ 3 Specifications ......................4 4. Performance Curve ....................7 5. Refrigerant Cycle Diagram ..................9 6. Outlines and Dimensions ..................10 7. Wiring Diagram ....................12 Safety Precaution ....................17 9. Installation ......................21 10. Troubleshooting ....................30 11. Exploded View & Part List ................... 32 Note : Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment.
  • Page 3: Model Name

    1. Model Name Power Supply V1 : Single Phase Series C : C Series Capacity Index 10 : Based on Btu/hr Type of Air-Conditioner RHR : Single Split Condensing Unit (Heat Reclaim)
  • Page 4 Series B : B Series Capacity 068 : 68 Litre Type of Air-Conditioner YWS : Water Tank (WinterSpa)
  • Page 5: Features

    The water tank can be connected from one to four condenser units, depending on the tank size. Environmentally Friendly By recycling the water energy of the air-conditioner, the DAIKIN WinterSpa actually helps to conserve the environment. Various Sizes - (DAIKIN WinterSpa Specifications) The caters for individual needs and preferences, the DAIKIN WinterSpa water tank comes in various sizes that can be installed indoor or outdoor, hidden or visible.
  • Page 6: Specifications

    3. Specifications Specification (R22) WinterSpa - RHR-C Series OUTDOOR UNIT MODEL RHR10CV1 RHR15CV1 WALL MOUNTED Btu/h 10,000 13,000 CEILING CASSETTE Btu/h 10,000 13,000 TOTAL COOLING CAPACITY CEILING EXPOSED-CB Btu/h 13,000 (DEPENDING ON INDOOR UNIT) Btu/h CEILING EXPOSED-E 12,000 Btu/h 10,000 CEILING CONCEALED 13,000 POWER SOURCE V/Ph/Hz...
  • Page 7 WinterSpa - RHR-C&B Series RHR20CV1 RHR25CV1 RHR30BV1 OUTDOOR UNIT MODEL WALL MOUNTED Btu/h 19,500 24,000 30,000 CEILING CASSETTE Btu/h 20,000 25,000 TOTAL COOLING CAPACITY 30,000 CEILING EXPOSED - CB 25,000 Btu/h 20,000 (DEPENDING ON INDOOR UNIT) CEILING EXPOSED - E Btu/h 20,000 25,000...
  • Page 8 Tank Specifications TANK MODEL YWS068B YWS090B YWS114B Litre Tank Capacity Imp.Gallon Unit Diameter Unit Height (Tank Section Only) 1070 Empty Tank Unit Weight Full Tank WinterSpa Tank Type Vertical/Horizontal Inner Tank Construction Stainless Steel Maximum Water Pressure Outer Casing Oven Baked Powder Coated E.G Sheet Insulation High Density Polyurethane Safety Relief Valve Setting...
  • Page 9: Performance Curve

    4. Performance Curve Heating Time For YWS068B RHR10CV1 RHR15CV1 RHR20CV1 Heating Time For YWS136B RHR10CV1 RHR15CV1 RHR20CV1...
  • Page 10 Heat Loss Characteristic For YWS068B Time (hours) Heat Loss Characteristic For YWS136B Time (hours)
  • Page 11: Refrigerant Cycle Diagram

    5. Refrigerant Cycle Diagram...
  • Page 12: Outlines And Dimensions

    6. Outline and Dimension Outdoor Unit Model: RHR10/15CV1 Dimension Model 700 521 250 478 180 37.5 190 28 94 64 440 130 81 19 278 86 63 60 54.5 63 RHR10/15CV1 All Dimensions are in mm Outdoor Unit Model: RHR20CV1 Dimension Model RHR20CV1 855 628 328 520 10 70 190 100 120 105 603 126 135 15 23 362 92 63 71 60.5 63...
  • Page 13 Outdoor Unit Model: RHR25CV1 Dimension Model 855 730 328 520 180 32 190 81 104 113 603 126 185 15 23 362 116 83 62 83 83 RHR25CV1 All dimensions are in mm Outdoor Unit Model: RHR30BV1 125.5 590.0 124.8 69.1 All dimensions are in mm...
  • Page 14: Wiring Diagram

    7. Wiring Diagram Model : RHR10CV1...
  • Page 15 Model: RHR15CV1...
  • Page 16 Model: RHR20CV1...
  • Page 17 Model: RHR25CV1...
  • Page 18 Model: RHR30BV1...
  • Page 19: Safety Precaution

    8. Safety Precaution Before Installation Safety Precaution Before Installation BEFORE OPERATING, PLEASE READ THE FOLLOWING “SAFETY PRECAUTIONS” CAREFULLY To prevent injury to the user or other people and properties damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications.
  • Page 20 Symbol (with white background) denotes item that is PROHIBITED from doing. Symbol (with black background) denotes item that is COMPULSORY to be carried out. Caution Please confirm the following important points when installation • Grounding is necessary It may cause electrical shock if grounding is not perfect. Do not install the unit where leakage of flammable gas may occur •...
  • Page 21 Installation Of The Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements: • Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacles which block air intake or discharge.
  • Page 22 Final Checking • Ensure the following, in particular: 1) The unit is mounted solidly and rigidly in position. 2) Piping and connection are leak proof after charging. 3) Proper wiring has been done. • Trial run 1) Conduct a trial run after water drainage test and gas leakage test. 2) Watch out for the following: a) Is the electric plug firmly inserted into the socket? b) Is there any abnormal sound from the unit?
  • Page 23: Installation

    9. Installation for Water Heater Tank Installation For Water Heater Tank Water Heater Tank The tank should be installed close to the majority of water outlets to reduce heat loss, as well as saving material and labour costs. In addition consider the following issues, which have an effect on operational performance, personal health and asset safety: •...
  • Page 24 9.2 Plumbling. (Refer to the Tank Installation Diagram 9.21) Plumbing must be done by a qualified person in accordance with the local water supply regulations for main pressure storage tanks. However we recommend: • Flush the water system thoroughly before fitting water tank and tempering valve. If the water supply is of poor which caused the tampering valve to be block, fit an additional filter or the strainer to the water inlet system.
  • Page 25 Tank Installation Diagram 9.22...
  • Page 26 Controller DGS01 TURBO QUIET SLEEP MODE TIMER CANCEL CLOCK CANCEL Operating Guide Transmission Source • The source where the signal will be transmitted. Signal Transmission Indication • Blink to confirm that the last setting has been transmitted to the unit. “ON/OFF”...
  • Page 27 • Press the MODE button to select the type of operating mode. • For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( Automatic air swing • Press the SWING ( ) button to activate the automatic air swing function. •...
  • Page 28 DSLM8 MODE TURBO SWING QUIET TIMER TIMER TIMER OVERRIDE SLEEP Operating Guide MODE Button Press the MODE button to switch operation from COOL, AUTO*, DRY*, FAN. Check the display to see in which mode the control is set. *AUTO and DRY are available for selected models only. TURBO Fan Speed Press the Turbo key once to activate Turbo fan speed.
  • Page 29 “ON TIMER” and “OFF TIMER” The unit has 2-event timer, namely Timer 1 and Timer 2, each event has an ON TIMER and an OFF TIMER. The key press activity for Timer ON and Timer OFF is shown on Table 1.1 Table 1.1: Timer ON and Timer OFF key press and event sequence.
  • Page 30 OVERRIDE Function Press the OVERRIDE key once will activate the override function for 1 hour. An indicator “OVERRIDE 1” will show on the LCD. Press the same key again will increase the setting to 2 hours. An indicator “OVERRIDE 2” will be shown. Subsequent press will deactivate the override function. After the override timer is completed, the override function is deactivated and the logo is OFF.
  • Page 31 OPERATING STATE AND FAULT TABLE Wireless Remote Control (Universal Board) Cooling : LED Indicator Light Display POWER TIMER SLEEP Operation / Faulty Indication POWER TIMER SLEEP Cool Mode Timer On Sleep Mode On Compressor Overload 1 Time Pump Fault 2 Times Gas Leak 3 Times Room Sensor Open or Short...
  • Page 32: Troubleshooting

    10. Troubleshooting By means of pressure readings : PRESSURE PROBABLE CAUSE Circuit 1. Overcharged with refrigerant. High Side 2. Non-condensable gases in refrigerant circuit (e.g. oil). Low Side 3. Obstructed air-intake/discharge. 4. Short circuiting of hot air at condensing unit. High Side 1.
  • Page 33 The most common causes of air conditioner failure to “start” are : a) Voltage not within +/ - 10% of rated voltage. b) Power supply interrupted. c) Control settings improper d) Air Conditioner is disconnected from main power source. e) Fuse blown or circuit breaker off. II) DIAGNOSIS OF REFRIGERANT CIRCUIT /APPLICATION There might be some cases where the unit starts running but does not perform satisfactory, i.e.
  • Page 34: Exploded View & Part List

    11. Exploded View & Part List Model: RHR10CV1 PARTS DESCRIPTION PARTS DESCRIPTION ASSY., BASE PAN BRACKET, MOTOR ASSY., OUTDOOR COIL MOTOR, MSL 10C AL-501 230V 6P 20W IPH ASSY., COMPRESSOR (2PS164D2AA01) FAN, 16 INCH (OZ42000) ASSY., PARTITION ASSY., INS, PANEL LEFT PLATE, FLARE VALVE ASSY., INS.
  • Page 35 Model: RHR15CV1 PARTS DESCRIPTION PARTS DESCRIPTION ASSY., BASE PAN BRACKET, MOTOR ASSY., OUTDOOR COIL MOTOR, MSL 15C AL-501 6P 30/32W IPH 230V ASSY., COMPRESSOR (2PS206D2AA06) FAN, 16 INCH (OZ42000) ASSY., PARTITION ASSY., INS, PANEL LEFT PLATE, FLARE VALVE ASSY., PANEL SERVICE ASSY., SERVICE VALVE 3/8”...
  • Page 36 Model: RHR20CV1 PARTS DESCRIPTION PARTS DESCRIPTION ASSY., BASE PAN PANEL, RIGHT BACK ASSY., OUTDOOR COIL (SL18C) 7MM COIL PANEL, FRONT/LEFT ASSY., MOTOR BRACKET PLASTIC, FRONT GRILLE MOTOR, MSL20C-502 6P 32W IPH 230V ASSY, PANEL TOP FAN PROPELLER, 455MM PZ455C2 PLASTIC, HANDLE ASSY., VALVE PLATE-FLARE VALVE (HR20C) TUBE, SUCTION COMPRESSOR, ASSY SH315RV-C8LU HITACHI...
  • Page 37 Model: RHR25CV1 PARTS DESCRIPTION PARTS DESCRIPTION ASSY., BASE PAN PANEL, RIGHT BACK ASSY., OUTDOOR COIL (SL25C-IRX34THX20FPI) PANEL, FRONT BRACKET, MOTOR PLASTIC, FRONT GRILLE MOTOR, MSL25C-504 6P 60W IPH 230V ASSY, PANEL TOP FAN PROPELLER, 455MM PZ455C2 PLASTIC, FRONT GRILLE ASSY., VALVE PLATE MAIN (HR25C) TUBE, SUCTION COMPRESSOR, ASSY 2JS438D3CB04 PANASONIC TUBE, DISCHARGE...
  • Page 38 Model: RHR30BV1 PARTS DESCRIPTION COMPRESSOR PANEL, SIDE ASSY., FRONT PANEL ASSY., BACK GRILLE PANEL TOP BRACKET, MOTOR MOTOR ASSY., TERMINAL BOX ASSY., INS. ACCESS VALVE...
  • Page 39 Model: YWS068B/090B/114B/136B/180B/340B PARTS DESCRIPTION BRACKET INNER BODY HEAT EXCHANGER INSPECTION COVER COLD WATER INLET HOT WATER OUTLET PIPE INSULATION OUTER BODY INLET FOR HOT GAS OUTLET FOR HOT GAS...
  • Page 40 . c o m . m y GROUP ASSOCIATED (C&L) SDN BHD (109719-M) Head Office: Tel: 03-7953 8388 Fax: 03-7956 4371 Email: sales_enquiry@daikin.com.my, customer_service@daikin.com.my Branches: • Penang Tel: 04-331 1670 • Johor Tel: 07-557 7788 •...