To Set Ignition Feed of the charger to AUTO-ON

Connect the Ignition Pin (in Fig.4: Terminals & 8 Pin Connectors diagram) to the car's hot wire (that is the
wire that has a positive dc 9 to 32V when car's ignition is turned on).
The charger only operates when the car is running, and charger stops charging once ignition is off.

To Set Ignition Feed of the charger to Manual ON-OFF operation

You can wire up a push switch with one end to the Vout for Ignition Pin and the other to Ignition Pin, see
Fig.4 Terminals & 8 Pin Connectors diagram. Shorting both pins will turn on the charger, disconnect will turn
off the charger.
How to deactivate the Ignition Feed mode
The Ignition Feed Mode will stay with the charger it has been activated once, even if the charger is taken out
from the system and re-installed in another car. That is once the Ignition Feed Mode has been activated,
charger will only be turned on when there is a positive voltage (+9V to +32V) at the Vout for Ignition Pin,
otherwise the charger stays in off mode.
Reset charger to factory default state with Ignition Feed in deactivated mode, such that the charger will start
charging the house battery as soon as input and output connections are made.
To deactivate the Ignition Feed mode:
1.
Disconnect any wire to the Ignition Pin in the charger.
2.
Press and hold Set Button for about 15 seconds until 3 battery type LED flash.
3.
Release button to complete the deactivation of the Ignition Feed Mode.

Enable build-in vibration sensor

Over ride of Ignition Feed by Vibration Sensor
Built-in vibration sensor when enabled dominates the control of output and over rides all other Modes
including the Ignition Feed. That is only vibration can make the charger start charging with output ON.
To disable the Vibration Sensor:

Indicators and Controls

Fig. 2 showing 7 LEDs indicators and one SET button
The built-in vibration sensor is enabled by connecting the T+ pin to Vout for
Ignition pin. The vibration sensor is in standby mode with output is OFF (no
charging). When sensor is triggered by vibrations which cause it to go the
active mode and after 8 seconds of further vibrations. The output will be
switched ON for about 100 seconds continuously.
Any further vibration during the 100 seconds active mode, will extend the
output ON for another 100 seconds. The output will be switched OFF if no
more vibration within 100 seconds of last vibration.
Take out the connection between the T+pin from Vout for Ignition pin.