Technical features

Input voltage
Output
Anti-triggering contact
Badge entry
Code entry
Master code
Input
Keyboard
Distance between the
second reader and the
DGPROX unit
Warning: Do not use a switching power supply because of radiation
interference, which may disturb the reading of the badges.
Default values
Master code:
Relay time delay:
Key-in keypad:
Alarm:

Audible signals

1 beep (long) Validation of data in programming mode: master code,
proximity badge or time delay.
Or access code validated
2 beeps (short) Accessing the programming mode
or exiting from the programming mode
4 beeps (short) incorrect mode, user number time delays entered

Visual signals

LED color
Green
Red
Orange
Orange flashing

Request-to-exit

The request-to-exit push button PB1 operates relay RL1.
The LED turns green when the relay is activated.
12 VAC/DC
2 relays, N/O & N/C contact 3A /125V
500 mA 50 V ~ or =
500 programmable badges
500 programmable codes, 5-digit PIN code
5-digit programmable code
1 request-to-exit
12-digit keypad with built-in buzzer (audible signal)
minimum 24 inches (60 cm)
maximum 45 yards (50 meters)
(cable minimum 7 x 0.6 mm
12345
1 second
10 seconds
Off
Normal mode
Door relay activated
Alarm relay activated
Stand-by
2
AWG22)
Programming mode
Code/Badge position empty
Code/Badge position busy
Programming mode
Data computing error
2