Subject: Warning – Metal Halide Display/Optic Lamps [HMI, HMD, HMP, HSD, HSR, HTI, HCD]
WARNING:
In accordance with ANSI/IESNA Standard RP-27, Display/Optic metal halide lamps are a Risk
Group 3 product.
Read and understand this warning before using this lamp!
THIS LAMP EMITS ULTRAVIOLET AND INFRARED RADIATION. ALWAYS WEAR
SUITABLE EYE PROTECTION WHEN WORKING NEAR THIS LAMP. THIS LAMP
OPERATES AT HIGH PRESSURE AND AT HIGH TEMPERATURE AND MAY
SHATTER UNEXPECTEDLY. THIS LAMP MUST BE USED IN A FIXTURE THAT
HAS A SUITABLE PROTECTIVE SHIELD AND/OR SCREEN TO PROTECT PEOPLE
AND SURROUNDINGS AGAINST THE RISK OF PERSONAL INJURY AND/OR
PROPERTY DAMAGE FROM LAMP SHATTERING AND EXPOSURE TO INFRARED
OR ULTRAVIOLET RADIATION.
RUPTURE & RADIATION (UV-IR-VISIBLE) HAZARD:
1. All Display/Optic metal halide lamps operate at high internal pressures (upwards of 500psi or
35bar possible) and may unexpectedly rupture resulting in the discharge of hot fragments
(approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of
mercury/mercury vapor. In the event of such a rupture, there is a risk of personal injury, burns
and fire.
2. All Display/Optic metal halide lamps generate ultraviolet (UV), infrared (IR) and visible
radiation during operation. This radiation can cause permanent damage to the eyes (including
blindness) and serious injury to the skin (including burns and blistering). To avoid eye
damage, other personal injury and/or property damage, the lamp MUST be operated in a
suitable fixture.
3. A suitable fixture is one that will prevent the arc from being viewed directly while operating,
and in the event of a lamp rupture, will prevent hot (up to 800°C / 1472°F), flying fragments of
quartz and/or metal from escaping into the area.
4. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see
OSRAM SYLVANIA product catalog for rated life) or when the lamp shows signs of
blackening.
5. The discharge vessel of Display/Optic metal halide lamps is constructed of quartz glass that is
filled with a quantity of mercury, elemental metals and/or rare earth elements. These lamps
are not at positive pressure when cold (not operating, at room temperature).
# # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # #
GENERAL SAFETY & INSTALLATION TIPS

BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):

Please verify that you have the latest revision prior to use. Do not use if outdated.
Printed on: 9/29/2006 9:21:00 AM
Industry Relations & Standards
Page 1 of 6
DQ4-144-067
Document No.:
E
Revision No.:
09-08-2006
Issue Date:
H/Warnings/OSRAM/MHID.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SYLVANIA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Osram SYLVANIA Series

  • Page 1 4. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life) or when the lamp shows signs of blackening.
  • Page 2 11. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector. Electrical connections Please verify that you have the latest revision prior to use. Do not use if outdated. H/Warnings/OSRAM/MHID.doc Printed on: 9/29/2006 9:21:00 AM Page 2 of 6...
  • Page 3 2. Operate with compatible power supply and fixture only. 3. OSRAM Display/Optic metal halide discharge lamps are designed for either hot re-start (high ignition voltages) or cold start (low ignition voltages only). Please see OSRAM literature for power requirements for your specific lamp type.
  • Page 4 Subject: Warning – Metal Halide Display/Optic Lamps [HMI, HMD, HMP, HSD, HSR, HTI, HCD] Display/Optic metal halide lamps may only be used in the operating positions described in the OSRAM SYLVANIA product catalog. Please note that lamp photometric values and arc stability can be effected by the operating position.
  • Page 5 2. Transportation in non-original packaging can damage the lamp and void warranty. 3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLY in DOT- compliant packaging. Original OSRAM packaging is DOT-compliant. MERCURY FILL OF DISPLAY/OPTIC METAL HALIDE LAMPS: • Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin “hydrargyrum,”...
  • Page 6 2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll-free, by calling 1-866-666-6850. 3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities. It is the responsibility of the waste generator to ensure proper classification and disposal of waste products.

Table of Contents