Summary of Contents for tado° 230v

  • Page 1 United Kingdom Part 1 of 2 Smart Thermostat 230 V Relay Installations Guide for Professional Installers If you are not a professional installer and want to install tado° yourself, get step-by-step instructions at tado.com/start...
  • Page 3: Table Of Contents

    Contents Optional Accessory 1. Wiring Smart Thermostat Combi Boilers (Dry Contacts) Extension Kit Combi Boilers (Dry Contacts) Extension Kit S-Plan Setups (Switched Live) Extension Kit Y-Plan Setups (Switched Live) 2. Connect Internet Bridge to Router 3. Pair Extension Kit with Internet Bridge 4.
  • Page 4 Do not use the tado° relay to switch the main electrical supply to the boiler! CAUTION: High voltage cables Make sure to turn the power off before you start 08/2018...
  • Page 5: Optional Accessory

    Optional Accessory tado° Trim Plate Use the behind the Smart Thermostat or Extension Kit if needed. This can be obtained separately at tado.com/trim-plate...
  • Page 6: Wiring

    1. Wiring: Smart Thermostat Combi Boilers (Dry Contacts) Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Boiler MAX 230 V AC 6(4) A Smart Thermostat Parking Terminals The Smart Thermostat can also be installed wirelessly when the Extension Kit is wired (p.
  • Page 7 1. Wiring: Extension Kit Combi Boilers (Dry Contacts) Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Boiler COM NC Extension Kit MAX 230 V AC 6(4) A Jumper Position 1...
  • Page 8 1. Wiring: Extension Kit S-Plan Setups (Switched Live) Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Hot Water Valve Heating Valve Hot Water Tank Boiler Extension Kit MAX 230 V AC 6(4) A Jumper Position 2...
  • Page 9 1. Wiring: Extension Kit Y-Plan Setups (Switched Live) Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Valve Hot Water Tank Boiler Extension Kit MAX 230 V AC 6(4) A Jumper Position 2...
  • Page 10: Connect Internet Bridge To Router

    2. Connect Internet Bridge to Router If no free USB jack available - plug to power socket Connect Internet Press pairing button until the Bridge to router LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge...
  • Page 11: Pair Extension Kit With Internet Bridge

    3. Pair Extension Kit with Internet Bridge Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 3 SEC Blinking 4x short - pause - ... 2 MIN Fast Blinking Press button for 3 sec Paired until LED starts blinking fast If failed: Blinking...
  • Page 12: Pair Smart Thermostat With Internet Bridge

    4. Pair Smart Thermostat with Internet Bridge 2 MIN 3 SEC Remove Press button Pairing Paired battery strip and for 3 sec - press button release If failed: • Press the button to clear the error • Restart pairing and make sure that the distance between the devices is at least 3 m while pairing...
  • Page 13 Open Installer Menu 2 MIN 3 SEC 3 SEC Press button Press button Installer Menu is Ready for for 3 sec - for 3 sec - loading configuration release release If failed: • Repeat the process to open Installer Menu •...
  • Page 14: Configuration

    5. Configuration Wired Setup: Smart Thermostat is wired directly to the boiler Heating Select Relay Circuit Hot Water HC01 Control Smart Thermostat Wireless Setup: Smart Thermostat installed wirelessly with receiver Select Heating Activate Temperature Circuit Hot Water Sensor HC01 Control for S- and Smart Thermostat &...
  • Page 15 2 MIN Extension Kit Installation complete 1. Set the timer on the boiler to “always heating” 2. Test the system 3. Hand over the registration R01 for fully pumped systems card to the customer R02 for gravity-fed systems 2 MIN Extension Kit Select Relay...
  • Page 16 Get expert advice on the tado° installer hotline: 020 3893 2159 or at tado.com/installers 102022_E...