Features - Sony Trinitron PVM-1353MD Operating Instructions Manual

Color video monitor
Hide thumbs Also See for Trinitron PVM-1353MD:
Table of Contents

Advertisement

Available languages

Available languages

Features

Picture
HR (High Resolution) Trinitron picture tube
HR Trinitron tube provides a high resolution picture.
Horizontal resolution is more than 600 TV lines at the
center of the picture.
Comb filter
When NTSC video signals are received, a comb filter
activates to increase the resolution, resulting in fine picture
detail without color spill or color noise.
Beam current feedback circuit
The built-in beam current feedback circuit assures stable
white balance.
Inputs
Two color systems available
The monitor can display PAL, and NTSC signals. The
appropriate color system is selected automatically.
Analog RGB/component input connectors
Analog RGB or component (Y, R-Y and B-Y) signals from
video equipment can be input through these connectors.
Press the RGB/COMPONENT A/B select button on the
front panel and select RGB or component signals from the
on-screen menu.
Y/C input connector (S input connector)
The video signal, split into the chrominance signal (C) and
the luminance signal (Y), can be input through this
connector, eliminating the interference between the two
signals, which tends to occur in a composite video signal,
assuring video quality.
External sync input connectors
When the external RGB or component signal is input and
sync signal is set to external in the on-screen menu, the
monitor can be operated on the sync signal supplied from
an external sync generator.
Automatic termination
(only terminals with the
The BNC input connectors on the rear panel are terminated
at 75 ohms inside, when no cable is connected to the loop-
through output connectors. When a cable is connected to an
output connector, the 75-ohm termination is automatically
released.
mark)
Functions
On-screen menus
You can set color temperature, CHROMA SET UP, and
other settings by using the on-screen menus.
Overscan mode
The display size is enlarged by approximately 20% and the
center part of the screen is easier to watch.
Underscan mode
The signal normally scanned outside of the screen can be
monitored in the underscan mode.
Note
When the monitor is in the underscan mode, the dark RGB
scanning lines may appear on the top edge of the screen.
These are caused by an internal test signal, rather than the
input signal.
Split function
The display splits into two parts (upper and lower). The
upper part of the screen monitors the signal fed through the
RGB/COMPONENT A input connectors and lower part of
the screen monitors the signal fed through the RGB/
COMPONENT B input connectors. You can compare the
two screens.
Caption vision (Closed Caption) decoder
When a signal with Caption Vision is input, the caption is
superimposed on the screen. You can select ON or OFF and
set the caption type on the on-screen menu.
Auto/manual degaussing
Degaussing of the screen can be performed automatically
when the power is turned on, or manually by pressing the
DEGAUSS button.
Five menu languages
You can select the language used for on-screen menus from
the five languages.
Splash proof cover(s) and control panel cover
Splash proof covers that protect the ventilation holes from
splashes (of medicines, etc.) and a control panel cover that
protects the control buttons on the front panel from
undesired touching are supplied.
Quick Reference Card
The Quick Reference Card is supplied to help you
understand the menu configuration and operating method.
You can attach the supplied double-sided adhesive tapes on
the rear of the card.
EIA standard 19-inch rack mounting
By using an MB-502B (for PVM-1353MD) or SLR-103
(for PVM-1953MD) Mounting Bracket (not supplied), the
monitor can be mounted in an EIA standard 19-inch rack.
For details on mounting, see the instruction manual of the
mounting bracket kit.
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron pvm-1953md

Table of Contents