E2S D1xB2XH1 Instruction Manual

Xenon beacons

Advertisement

Quick Links

Instruction Manual
D1xB2XH1 & D1xB2XH2 Xenon Beacons
For use in hazardous Locations
Marking Information
Unit Type No.: D1xB2XH1
D1xB2XH2
Input Voltage: DC Unit
D1xB2XH1:
Codes:
Class / Division Ratings for US
Class I Div 1
Class I Div 1
Class / Division Ratings for Canada
Class I Div 1
Class I Div 1
Class / Division Ratings for US and Canada
Class II Div 1
Class II Div 1
Class II Div 1
Class III Div 1
Class / Zone ratings for US
Class I Zone 1
Class I Zone 1
Zone 21
Class / Zone ratings for Canada
Ex db IIC T5
Ex db IIC T6
Ex tb IIIC 107°C Ta -55°C to +80°C
D1xB2XH2:
Class / Division Ratings for US
Class I Div 1
Class I Div 1
Class I Div 1
Class / Division Ratings for Canada
Class I Div 1
Class I Div 1
Class I Div 1
Class / Division Ratings for US and Canada
Class II Div 1
Class II Div 1
Class III Div 1
Class / Zone ratings for US
Class I Zone 1
Class I Zone 1
Class I Zone 1
Zone 21
Class / Zone ratings for Canada
Ex db IIC T4
Ex db IIC T5
Ex db IIC T6
Ex tb IIIC 131°C Ta -55°C to +80°C
The certification approval has validated continuous use up to 38C ambient and are for transient use up to 80C ambient
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, London, W3 7QH, UK
Document No. D191-00-251-IS-SC_Issue_E
Range : 20-28Vdc
10J Xenon Beacon
Group ABCD
T5
Group ABCD
T6
Group CD
T5
Group CD
T6
Group EFG
T4A
Group EFG
T5
Group EFG
T6
Ta -55°C to +80°C
AEx db IIC T5
Ta -55°C to +80°C
AEx db IIC T6
Ta -55°C to +60°C
AEx tb IIIC 107°C Ta -55°C to +80°C
Ta -55°C to +80°C
Ta -55°C to +60°C
21J Xenon Beacon
Group ABCD
T4A
Group ABCD
T5
Group ABCD
T6
Group CD
T4A
Group CD
T5
Group CD
T6
Group EFG
T4
Group EFG
T4A
Ta -55°C to +80°C
AEx db IIC T4
Ta -55°C to +80°C
AEx db IIC T5
Ta -55°C to +55°C
AEx db IIC T6
Ta -55°C to +40°C
AEx tb IIIC 131°C Ta -55°C to +80°C
Ta -55°C to +80°C
Ta -55°C to +55°C
Ta -55°C to +40°C
27/04/2018
Ta -55°C to +80°C
Ta -55°C to +60°C
Ta -55°C to +80°C
Ta -55°C to +60°C
Ta -55°C to +80°C
Ta -55°C to +65°C
Ta -55°C to +50°C
Ta -55°C to +80°C
Ta -55°C to +55°C
Ta -55°C to +40°C
Ta -55°C to +80°C
Ta -55°C to +55°C
Ta -55°C to +40°C
Ta -55°C to +80°C
Ta -55°C to +60°C
sales@e-2-s.com
www.e-2-s.com
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200
Sheet 1 of 7

Advertisement

loading

Summary of Contents for E2S D1xB2XH1

  • Page 1 Instruction Manual D1xB2XH1 & D1xB2XH2 Xenon Beacons For use in hazardous Locations Marking Information Unit Type No.: D1xB2XH1 D1xB2XH2 Input Voltage: DC Unit Range : 20-28Vdc D1xB2XH1: 10J Xenon Beacon Codes: Class / Division Ratings for US Class I Div 1 Group ABCD Ta -55°C to +80°C...
  • Page 2 WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD - CLEAN ONLY WITH A DAMP CLOTH HIGH VOLTAGE SHOCK HAZARD. WAIT 5 MINUTES AFTER REMOVING POWER BEFORE OPENING THE ENCLOSURE DO NOT PAINT TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, CONDUIT RUNS MUST HAVE A SEALING FITTING CONNECTED WITHIN 18 INCHES OF ENCLOSE...
  • Page 3 * Flash rates Public Mode Fire # nominal rms current at nominal voltage ## max. rms current at worst-case voltage in voltage range. Surge Current for Fire Alarm use per UL Listing Surge Currents Nom. Voltage Flash Rate Setting Init, Peak Surge Init.
  • Page 4 Min. voltage at point of use + voltage drop Flash Rate Settings The D1xB2XH1 & D1xB2XH2 beacons can produce different flash patterns as shown in Table. The flash patterns are selected by operation of the flash setting DIP switch on the PCBA...
  • Page 5 NFPA standards and guidelines or CEC regulations. Horizontal Light Output Dispersion for wall mounting – public mode Horizontal dispersion angles for wall mounting D1xB2XH1 - Horizontal Light Output Dispersion for Wall Mounting Intensity (cd) at Intensity (cd) at Intensity (cd) at Viewing Angle...
  • Page 6 Vertical Light Output Dispersion for wall mounting – public mode Vertical dispersion angles for wall mounting D1xB2XH1 - Vertical Light Output Dispersion for Wall Mounting Intensity (cd) at Intensity (cd) at Intensity (cd) at Viewing % Of Rating 1Hz flash rate 1.5Hz flash rate...
  • Page 7 Vertical Light Output Dispersion for ceiling mounting – public mode Vertical dispersion angles for ceiling mounting X and Y planes D1xB2XH1 - Vertical Light Output Dispersion for Ceiling Mounting Intensity (cd) at Intensity (cd) at Intensity (cd) at Viewing Angle...

This manual is also suitable for:

D1xb2xh2