When the MONITOR relays are activated, the MONITOR circuits get
their signal from the TAPE RETURN input.
The MONITOR circuits
feed the CUE SENDS, the ECHO SENDS, and the QUAD MIX BUSES in
the same way they did in HIKE mode.
In this mode, the meters read the TAPE RETURN level.
The only difference between MIKE mode and TAPE mode is that in
MIKE mode the monitors are listening to the program material
BEFORE it goes to the TAPE MACHINE, while in TAPE mode, the
.
monitors are listening to the program material AFTER it has been
sent to the Tape machine and returned via the TAPE RETURN line.
NoTE THAT THIS DOES NOT MEAN THAT YOU ARE LISTENING TO THE
CHANNEL AFTER IT HAS BEEN RECORDED.
THE TAPE RETURN LINE
MONITORS THE lfJPUT TO THE TAPE f'lACHINE DURING
RECQqD
f·10DE.
TAPE mode is normally used to listen to what you have recorded
without having to change the monitor mix.
The monitors are fed
from the TAPE RETURN LINE.
When the Tape machine is in PLAY mode,
the TAPE RETURN LINE monitors the output of the PLAY head.
ANY INDIVIDUAL 1/0 f·10DULE CAN BE SWITCHED BACK TO MIKE MODE FROM
TAPE MODE BY PRESSING THE f'-10N BUTTON,
THIS fv1UST BE DONE IN
OVERDUBS I NG,
(The MON button releases the MONITOR relay.)
3
I
3
RH1I X
~-10DE
In this mode, BOTH the
MO~UTOR
relays and the REMIX relays are
activated.
The REMIX relay switches out the Mike input and connects the TAPE
RETURN INPU'ifl to the CHANNEL FADER.
The EQ circuits and the CHANNEL
BUS and the CHANNEL ASSIGNMENT structure is being fed from the
TAPE RETURN.
The EQ output also feeds
(through the REMIX relay contacts)
the MONITOR circuits.
CUE SENDS, ECHO SENDS, and the QUAD lUX
BUSES are all fed from the output of the EQ.
Note that the TAPE
~~CHINE
OUTPUT terminals are live, and may be
used as additional SENDS.
In this mode, the meters read the TAPE
RETUR~
level.
ANY INDIVIDUAL 1/0 r10DULE CAN BE St•JITCHED BACK TO TAPE MODE FR0~1
REMIX MODE BY PRESSING THE FDR BUTTON.
TO SWITCH THE MODULE FROM
REMIX MODE TO MIKE MODE, PRESS BOTH THE FDR BUTTON AND THE MON
BUTTON,
(The FDR button releases the REMIX relay, the MON button releases
the MONITOR relay.)