  • Page 1 USER MANUAL...
  • Page 2 USER AND MANTINANCE MANUAL SERVE OVER COUNTER WARNING GUARANTEE INSTALLATION AND ASSEMBLY TECHNICAL CHARACTERISTICS AND CONDITIONS OF USE START-UP RECOMMENDATIONS PRECAUTIONS MAINTENANCE OPERATIONAL TESTS 10. DECOMMISSIONING 11. ELECTRIC SHEME 12. COLD SHEME - ANNEX NORMATIVE INICIAL NOTICE Before turning the unit on we recommend you to read the instructions and follow the steps as explained...
  • Page 3 We would like thank you for your confidence in us for having purchased this refrigerated unit. This manual has been prepared ing order to safeguard the security of the user and ensure the correct use and maintenance of the refrigerated units. Please read it carefully before starting up your unit.
  • Page 4: Installation And Assembly

    3. INSTALLATION AND ASSEMBLY The unit must not be moved from its standard vertical position, however as necessary, some appliances may be placed face down only as indicated on the packaging. You are advice to unpack the unit standing on a solid, flat and stable surface. In order to transfer it to the installation location, a trolley or fork-lift may be of help.
  • Page 5 4. TECHNICAL CHARATERISTICS AND CONDITIONS OF USE The technical data of the unit, model and serial number are identified by means of the information displayed on the registration or on the data sheet that appears on all the products. Apart from the identifying data of the unit, information relating to the gas refrigerant and electrical voltage to which the unit must be connected is also displayed.
  • Page 6 • The unit should not be used in threatening atmospheric or fire risk conditions. • Check that there are no defects on the unit resulting from its transportation. The manufacturer will not be liable for damage suffered during transportation or arising from incorrect storage. •...
  • Page 7 To set the new value, press and appears the value of the temperature of the room probe. ELIWELL: Although it is possible to select or reprogram the temperature by manipulating the thermostat, it is not advisable, as this may cause the improper operation of the unit, changing the purpose for which it was programmed, and for this reason such manipulation should never be done.
  • Page 8: Maintenance

    • Protect foods and their odours by using some hermetic closing system, placing them in the unit in such a way that allows for a good circulation of air, respecting the maximum load indicated on the inside of the unit. •...
  • Page 9 • EVAPORATORS Only for specialist personnel The only maintenance the evaporators require is proper cleaning. This has to be done with the machine stopped and once the ice that may be present on the fins has melted or once defrosting has been done by operating the controls. This process may be accelerated by using warm water, NEVER using hard or sharp objects.
  • Page 10 • NOISE TESTING - The noise tests were performed in a room without any noise absorption elements and without any large item placed near to the refrigerated unit. - The noise levels registered in the acoustic test have been carried out in accordance with the ISO 230 to 235 standards. Leq (continuous level) is less than 70 dB.
  • Page 11 11. ELECTRIC SCHEME. Models DD0150SG-DD0200SG Models DD0250SG-DD0300SG Models DD0150CG-DD0200CG Models DD0250CG-DD0300CG 12. COLD SCHEME.