INSTALLATION INSTRUCTIONS
S
L
P
MART
IMIT
ROTECTION
W - WHF SERIES
Wall Heaters
Models: 1210 (120V)
1212 (120V)
2010 (208V)
2015 (208V)
2410 (240V)
2412 (240V)
2420 (240V)
2424 (240V)
2710 (277V)
2715 (277V)
DANGER
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND SAFETY
DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY
It is extremely important to verify the electrical power supply is the same voltage as the heater being installed. 240 and
120 Volt heaters are not interchangeable. Powering a 208/240/277 Volt unit with 120 Volt supply wires will reduce heater
output by approximately 75%. Powering a 120 Volt unit with 208/240/277 Volt supply wires will destroy the heater and voids
all guarantees and warranties.
CAUTION: Keep electrical cords, drapery, furnishings and other combustibles at least 3 feet (.9m) from front of the heater
and away from side and rear. Do not block the heater in any manner. To insure proper operation of this heater it should be
a minimum of 4 inches above the fl oor and no closer than 6 inches to the open edge of a door and/or adjacent wall. Never
paint the heater grill.
WARNINGS: Turn off the power source supplying the heater before attempting any installation, maintenance or repairs.
Lock or tag circuit breaker/fuse panel door. Failure to do so could result in serious electrical shock, burns or possible death.
The superior quality and design of this heater will provide years of trouble-free performance. Each year the heater should be checked and cleaned for lint and/or dust accumulation. King
recommends using a soft bristle brush and vacuum to knock off contaminates. The motor is permanently lubricated and requires no oiling.
W Wall Heaters carry a one (1) year limited warranty on all components from date of installation. WHF Wall Heaters carry a two (2) year limited warranty on all components from date of
installation. This warranty requires that the owner or his agent install the equipment in accordance with the National Electrical Code, any other applicable heating or electrical codes, and
the manufacturer's installation instructions. It further requires that reasonable and necessary maintenance be performed on the unit. Failure to properly maintain the unit will result in the
warranty being voided. The company is not liable for abuse or misuse of product as may be fi nally determined by the company. The customer shall be responsible for all costs incurred
in the removal or reinstallation of products, including labor costs and shipping costs incurred to return products to King Manufacturing. King Manufacturing will repair or replace, at our
option, at no charge to the customer with return freight paid by King. King Manufacturing shall not be liable for consequential damages arising with respect to the product, whether based
upon negligence, tort, strict liability or contract. No other written or oral warranty applies, nor any warranties by representatives, dealers, employees of King, or any other person. All
returns require a King Return Goods Authorization (RGA); Unauthorized returns will be refused. Do not return malfunctioning/defective products to store.
Operating voltage cannot exceed 5% of rated voltage. Operating heater above listed voltage ratings voids all guarantees and warranties.
KING ELECTRICAL MFG. COMPANY · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com
SAVE THESE INSTRUCTIONS
®
1215 (120V)
2020 (208V)
2415 (240V)
WARNING
MAINTENANCE & WARRANTY
w-whf.indd : 4/08
SMART
SLP
®
LIMIT
PROTECTION
U.S. PATENT #6,748,163 B2 • CIPO PATENT #2,393,882
File #E41422

Advertisement

loading

Summary of Contents for KING W SERIES

  • Page 1 King Manufacturing. King Manufacturing will repair or replace, at our option, at no charge to the customer with return freight paid by King. King Manufacturing shall not be liable for consequential damages arising with respect to the product, whether based upon negligence, tort, strict liability or contract.
  • Page 2 CAUTION The heater should not be covered or blocked in any manner. KING ELECTRICAL MFG. COMPANY · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com w-whf.indd : 4/08 SMART ® LIMIT PROTECTION U.S.
  • Page 3: Exploded Views

    With electric heat you can add to the heating system, in large or small increments. KING ELECTRICAL MFG. COMPANY · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com w-whf.indd : 4/08 SMART ®...
  • Page 4 Heaters should be cleaned and inspected every 6 months. This guide will show in detail how to properly clean and maintain your King electric wall heater. It will also show when parts (or perhaps the entire heater) should be replaced. Listed below are step by step instructions for cleaning and maintaining the W and WHF Series Wall Heaters.