INSTALLATION INSTRUCTIONS
INSTALLATION
Following are installation guidelines:
• Disconnect power at main panel.
• Make certain all wiring is in accordance with any/all local codes.
• Ensure units are properly grounded.
• Heater voltage rating should be the same as supply load.
1. Remove two screws on front grill. Remove grill. Loosen mounting screw.
Remove fan heater assembly.
2. Remove a 7/8" knockout. Thread supply wire into wallbox. Use an approved
strain relief bushing to prevent chafi ng of supply wires through the opening in
wallbox.
3. Install wall can a minimum of 6" from vertical sidewalls and 4" above fl oor.
The front edge of wall can must be ½" beyond finished wall.
4. Secure wallbox to the 2x4 studs using the two (2) holes on each side of
wallbox. Secure twist lock to wall stud on opposite side.
5. Reinstall heater assembly at top of wallbox with mounting screw.
Connect supply and ground wires. (see diagram)
6. Reinstall grill securely with screws provided. For proper air circulation, the
top louver in grill must open into and between wall can and top of heater.
FIELD WIRING – 120/277 VOLT:
1. Connect power supply L1 (white neutral wire) to white heater wire.
2. Connect power supply L2 (black hot lead) to black heater wire.
3. Connect groundwire to green wire on wall can.
FIELD WIRING – 208/240 VOLT:
1. Connect power supply L1 (hot lead) to a black heater wire.
2. Connect power supply L2 (hot lead) to a black heater wire.
3. Connect groundwire to green wire on wall can.
NOTE: The two black leads on the heater can be connected to either hot lead.
There is no polarity. The 208/240 Volt heater does not require a neutral wire from
the power panel.
This heater includes a manual reset SLP thermal protector with a
SMART
self-hold feature. If the heater shuts off in the on position and the room
SLP
temperature is below the highest thermostat setting, immediately discon-
®
LIMIT
nect the power to the heater at the circuit breaker. Inspect for any objects
PROTECTION
U.S. PATENT #6,748,163 B2 • CIPO PATENT #2,393,882
on or adjacent to the heater that may cause high temperatures. After
inspecting the heater, keep the power to the heater off for 10 minutes to reset the SLP
thermal protector. If the SLP thermal protector shuts the heater off again, immediately turn
the heater off at the circuit breaker and inspect the heater for possible fan motor failure or
dirt and lint on the heating element. Repeat the starting procedure.
FAN-FORCED HEATERS:
Clearances for Safe Operation
KING ELECTRICAL MFG. COMPANY · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH: 206.762.0400 · FAX: 206.763.7738 · www.king-electric.com
SAVE THESE INSTRUCTIONS
Two Element - Factory Wiring
ELEMENT
TAG
POWER
SUPPLY
CAUTION
The heater
should not
be covered
or blocked
in any manner.
W - WHF WIRING DIAGRAM
Single Element Factory Wiring
FAN
TAG
LIMIT
ELEMENT
LIMIT
capped
ends
POWER
THERMOSTAT
SUPPLY
(OPTIONAL)
W DIMENSIONS
WHF DIMENSIONS
w-whf.indd : 4/08
FAN
LIMIT
LIMIT
THERMOSTAT
(OPTIONAL)
SMART
SLP
®
LIMIT
PROTECTION
U.S. PATENT #6,748,163 B2 • CIPO PATENT #2,393,882
File #E41422

Advertisement

loading

This manual is also suitable for:

Whf series12102010241024202710 ... Show all