Waeco ECL-76 Installation And Operating Manual page 83

Charging current distributor
Table of Contents

Advertisement

Available languages

Available languages

ECL-76, ECL-102, ECL-103
I
NOTE
If the circuit diagram also shows an on/off cable from the charging current
distributor to the air conditioner, the air conditioner (or compressor motor) will
be switched off when the voltage is low. Otherwise, an on/off cable is run from
the charging current distributor to the inverter or to the remote control of the in-
verter and the inverter is switched off.
A remote control (remote switch) is connected to the inverter with which the inverter must
be switched on before start-up or switched off when it is not in use.
The charging current distributors have two relays which are used as follows:
 Power relay (30/87 or Batt. 1/Batt. 2)
to connect the starter and consumer battery
 Control relay
– ECL-76/DC-Kit1, CA1000: to switch the compressor on and off (fig. 1, page 3)
– ECL-76/DC-Kit1, FreshJet1100: to switch the compressor on and off (fig. 2,
page 4)
– ECL-102/DC-Kit2, CA2500: to switch the compressor or air conditioner on and off
(fig. 3, page 5)
– ECL-102/DC-Kit2, B1600: to switch the compressor or air conditioner on and off
(fig. 4, page 6)
– ECL-102/DC-Kit2, B1600 Plus/B2200: to switch the compressor or air conditioner
on and off (fig. 5, page 7)
– ECL-102/DC-Kit2, FreshJet1100, FreshJet1700, FreshJet2200: to switch the com-
pressor or air conditioner on and off (fig. 6, page 8)
– ECL-102/DC-Kit2, FreshLight1600, FreshLight2200: to switch the compressor or
air conditioner on and off (fig. 7, page 9)
– ECL-102/DC-Kit3, CA1000, CA2500: to switch the compressor or air conditioner on
and off (fig. 8, page 10)
– ECL-102/DC-Kit3, B1600 Plus, B2200: to switch the compressor or air conditioner
on and off (fig. 9, page 11)
– ECL-102/DC-Kit3, B1600, HB2500 (systems without enable input): to switch the
compressor or air conditioner on and off plus to switch the inverter on and off using
its remote control (fig. 0, page 12)
– ECL-102/DC-Kit3, FreshJet1100, FreshJet1700, FreshJet2200: to switch the com-
pressor or air conditioner on and off (fig. a, page 13)
– ECL-102/DC-Kit3, FreshLight1600/2200: to switch the compressor or air condition-
er on and off plus to switch the inverter on and off using its remote control (fig. b,
page 14)
– ECL-102/DC-Kit3, FreshWell3000: to switch the compressor or air conditioner on
and off plus to switch the inverter on and off using its remote control (fig. c,
page 15)
– ECL-103/DC-Kit5, CA1000, CA2500: to switch the compressor or air conditioner on
and off (fig. d, page 16)
– ECL-103/DC-Kit5, B1600 Plus, B2200: to switch the compressor or air conditioner
on and off (fig. e, page 17)