Page 1
PATENTED INDUCTION POWERED Greengage TECHNOLOGY BY www.greengage.global/patents Installation Manual ALIS power, control and lighting platform Version CE and UL www.greengage.global...
All electrical installation work must conform to all local and international electrical wiring and safety regulations such as those published by CENELEC member organisations or those covered by IEC60364. Greengage Lighting Ltd is not responsible for safety on site and installers should contact Greengage Lighting Ltd technical support with any queries they may have at support@greengage.global Please follow these instructions carefully as deviation from them may invalidate the product warranty.
Warranty validation ............................23 Site Information ...................................... 23 Installer Information ....................................23 Install Information....................................24 Appendix ................................25 Connection diagram ....................................25 Page 3 of 27 Version 5.1 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018...
Multi Meter Light Meter Mounting accessories Catenary cable Twist Buckle Cable ties Eye hook Suspension chain Wire rope clamps 1 October 2018 Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp Page 4 of 27...
The Greengage induction system (ALIS) is a 'contactless' power technology that allows LED fixtures (ALIS Lamps) to be clipped onto the cable (ALIS Bus) without an actual physical electrical connection. It works on the principle of distributing a highly regulated alternating current at 50 kHz along the ALIS Bus to the ALIS lamps.
Do not submerse. (IP69K) ALIS ALS0007 ALS0007 Install only in dry Potentiometer locations. (or suitable enclosure to meet local regulations) 1 October 2018 Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp Page 6 of 27...
Page 8
Panel (2 x 500W) available in CE Only North ALS0010 America. (1 x 500W) 13. DTD Controller ALS0049 ALS0049 Page 7 of 27 Version 5.1 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018...
ALIS Dimmer, away from all combustible materials, sources of heat and out of direct sunlight. Clearances of 100mm (4 inches) from the top and bottom of the ALIS Power Hub and 75mm (3 inches) from the sides must be allowed for.
The ALIS Dimmer must be mounted within the same enclosure as the ALIS Power Hub, either horizontally or vertically in close proximity to the ALIS Power Hub. If this is not possible then the ALIS Dimmer enclosure must be used, mounted away from all combustible materials, sources of heat and out of direct sunlight.
Take note of the lamp position and place the first lamp as follows. At the desired lamp position un-twist, the ALIS Bus by no more than 5cm (2 inches). Place one wire from the ALIS Bus into the lamp coupler slot, as shown below, ensuring the ALIS Bus is clean and free from grit.
Slide the orange connector cover labelled SOCKET over the ALIS Power Hub ALIS Bus. Strip the outer insulation of the ALIS Bus to 30mm (1¼ inches) taking care not to damage the inner insulation. Strip the ends of the ALIS Bus inner insulation to 8mm (0.3 inch) of exposed conductor, ensuring there is not any conductor loss.
See also section 3.3 of this manual. Connect the ALIS End Termination Module (ETM) or shorting terminal block to the far open end of the ALIS Bus. The ALIS bus insulation must be properly stripped to ensure there is no to damage the cable conductors.
To ensure optimum operation and stability of the system, the following recommendations should be observed. If the length of the ALIS bus is less than 100m then the ALIS Bus must be terminated by means of a shorting connection to keep the ALIS Bus in resonance with the Hub.
3.6 System Connection a. Connect the ALIS Bus to the ALIS Dimmer as shown in the ALIS system components diagram (page 5). b. Connect the ALIS Dimmer to the ALIS Power Hub as shown in the ALIS system components diagram (page 5).
1. Double check the ALIS Bus cable length connected to the ALIS Power Hub. This should not exceed 150 metres. If in doubt contact support@greengage.global 2. Count the number of lamps per ALIS Bus per ALIS Power Hub. This should ideally not exceed 40 x 10W ALIS Barn Lamps (see also section 3.3). If in doubt contact support@greengage.global 3.
5. Fault finding If the ALIS Lamps flash ON and OFF, this means you have too much load on the system. Start unclipping the ALIS Lamps one at a time until the flashing stops. Recheck the recommended maximum number of lamps as shown in section 3.3 and 4.
ALIS Lamp(s) flashing or flickering. If this is the observed fault, then it is most likely that the ALIS Power Hub is not the problem. Ascertain whether it is a few lamps or all the lamps on the ALIS Bus. Is it continuous or only...
10. Please note that poorly made electrical connections are often the main cause of equipment failure, which in turn leads to livestock fatalities. 11. If the ALIS Bus passes through a hole or aperture (metal or otherwise) a suitable insulating grommet or gland must be fitted.
IP10 or NEMA Type 1. 95% RH is achieved with a dry bulb temperature of 55˚C and a wet bulb temperature of 54˚C. Page 19 of 27 Version 5.1 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018...
The specifications contained herein are believed to be correct at the time of publication and are subject to change without notice. Page 20 of 27 1 October 2018 Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp...
E470619 Light Emitting Diode (LED) Equipment for Lighting CSA C22.2 No.250.13-12 Applications General Use Power Supplies CSA C22.2 No.107.1-01 Page 21 of 27 Version 5.1 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp 1 October 2018...
EN 60598-2-24 2013 Luminaires - Part 2-24: Particular requirements - Luminaires with limited surface temperatures ALIS Nest Lamp is designated to have Class II type insulation and Barn Lamp to have Class III. 8. 4 ALIS Lamps (cULus) Parameter Standard UL file No.
Warranty validation To validate the two-year’s warranty of the ALIS system, please complete the form below and send to warranty@greengage.global or/and Warranty Registration Greengage Lighting Limited Sir Alexander Robertson Building, University of Edinburgh Easter Bush Campus, Midlothian, EH25 9RG, United Kingdom...
Please send pictures of the following a. The installed ALIS Power Hubs and ALIS Dimmers b. The ALIS Bus end termination Page 24 of 27 1 October 2018 Version 5 • CE and UL • ALIS Barn Lamp and ALIS Nest Lamp...