A. Using T6B As A Standalone Balancer B. Using T6B With A Charger C. Using T6B With A Discharger 6 - 7 USING T6B MAX WITH TAHMAZO T15 AC/DC OR T30V2 (USING THE INTERFACE CABLE) For Charging For Discharging MONITOR LED...
Page 3
Tahmazo T6B Max Active Balance Lithium Cell Balancer Heatsink Interface port Output for LiPo battery 10A fuse Battery condition LEDs Network port Power leads to LiPo charger Selectable switch Status LED for Master/Slave Mode/Reset switch...
‘balanced’. When a lithium pack is connected to the Tahmazo T6B Max, the T6B Max will start to balance or equalize the lithium cells in the pack. The Tahmazo T6B Max takes cell balancing one step further, giving precise cell voltage when it is interfaced with selected Tahmazo chargers*.
Active Balance - Cool Blue Balancer Specifications Parameter Mode Specifications Operating Voltage Output Battery Voltage 6.0 - 30V Charger Input Voltage 55V max Lithium Polymer Battery 3.7V nominal/cell Battery Type LiFe or A123 battery 3.0V nominal/cell No. of Cells Lithium battery pack 1 - 6 cells Lithium battery pack Max Current...
Then the Status LED will be lighted (‘ON’) when the balancer Switch T6B Max to ‘Master’ mode. Then connect the starts to balance the cells. battery pack with the proper harness to the balancer.
For Discharging now activated. (In connection mode, T6B Max Balancer is connected to the charger while the When the Tahmazo T6B Max Balancer is connected to battery pack is connected to T6B Max Balancer). the Tahmazo charger/discharger using the interface cable (included with T6B Max Balancer), the discharging •...
The flashing rhythm of the monitor LEDs is a guide to the balancing function may not reach a the voltage of the cells in the pack. conclusion even in “Disconnection mode”. If this should occur, the T6B Max will prevent the Monitor LED Indicates cells from becoming deep-discharged by switching...
2.0V per cell Quadruple rhythmic flashing. Connection Error. If you encounter this error, disconnect the battery pack from the T6B Max and T6B Max from the charger. Then reconnect them. If the problem...
• Connect the (–) negative (black) input cable of ‘Master’ T6B Max Balancer and (+) positive (red) input cable of ‘Slave’ T6B Max Balancer to a charger as shown Master-Slave Mode in Figure 1. The balancer should be set to Master when it is •...
Page 11
Active Balance - Cool Blue Balancer Figure 1...
• Set ‘Master’ mode for one balancer, and the other balancer to ‘Slave’ mode. • Connect the network cable between the two balancers. • Connect the ‘Master’ T6B Max Balancer’s data interface cable to the charger. • Connect the ‘Master’ Balancer to a charger.
Page 13
Active Balance - Cool Blue Balancer Figure 2...
Safety notes • Read the instructions provided by the battery and charger manufacturers, and adhere to them strictly. • The T6B Max Balancer is designed solely for balancing rechargeable lithium batteries • At regular intervals, check the case and cables for damages.
Active Balance - Cool Blue Balancer Service Procedure Disclaimer For servicing of your Tahmazo T6B Max Balancer, either Tahmazo Products Pte Ltd is not responsible for your in or out of warranty, you can send them to our nearest use of this product, or for any damages or injuries dealer to you, or by post paid and insured to: you may cause or sustain as a result of its usage.
Need help?
Do you have a question about the T6B Max and is the answer not in the manual?