Extract mode is used for processing an ethanol tincture, to separate the commingled oil
components and ethanol that together make up a tincture. When the process is complete, the oil
will remain in the kettle and the ethanol will be separated and collect in the reclaim jar.
Tip: It's advisable to do a test run with only ethanol to get the feel of the machine and make sure
everything is operating correctly.
STEP 1: Load Kettle With Tincture
It's best to load the kettle when it's already plugged into the base. Moving the kettle, plugging it in, or unplugging
it with tincture already loaded will easily cause sloshing and spillage that will be messy and dangerous. If it's
necessary to adjust the kettle once loaded, place the lid on top before doing so. Once the kettle is loaded and
ready to go, place the lid on the kettle and prepare to start the process.
STEP 2: Starting Extract Mode
• Use the dial to choose a setting in the red zone labeled EXTRACT. The approximate temp range for the red arc
is 96°F-105°F. The higher temperature is more aggressive and faster while the lower is less active and slower.
-The high end of the range would be used for fast normal processing.
-The low setting is used for overly thick contents, for less aggressive activity in the kettle, and to avoid
bumping on hot starts.
• Confirm the plugs on the kettle are fully engaged. If they are not plugged all the way in and fully connected the
kettle will not generate heat for operation.
• Confirm the reclaim jar lid and kettle lid are securely in place.
• Confirm the spit jar is empty and attached.
• Push the green illuminated 'START/STOP' button one time to start processing.
IMPORTANT: HOT START CONSIDERATIONS
When restarting EtOH PRO while the unit and contents are still warm there is a good chance for
"bumping" to occur. This means that as the contents come under vacuum and have heat reintroduced
there will be a big burp of liquid that will splatter aggressively. To avoid this either wait for everything to
cool down completely or turn the control dial to the lowest setting and restart the machine. Boiling should
be reestablished in under 10-minutes, when this happens adjust the control dial to the performance level
you prefer.
STEP 3: Establishing Vacuum Seals
•
Once EtOH PRO has been started the vacuum pumps will automatically begin providing vacuum pressure.
• The vacuum will establish in the reclaim jar first. Hold the vacuum lid in place, and once it is firmly held is
place with vacuum pressure place the outer ring on the lid and gently secure. Do not over tighten the ring.
• Next check to see if the kettle lid is firmly held in place by the vacuum. If the lid is not held down by the
vacuum place equal and gentle pressure on opposite sides of the plastic area of the lid for 10-30 seconds to
establish the vacuum seal.
USING EtOH PRO: EXTRACT MODE