ICP TSTAT0404 Installation Instructions And User Manual

ICP TSTAT0404 Installation Instructions And User Manual

Heat cool / heat pump thermostat 3 heat – 2 cool

Advertisement

Quick Links

997-060180-3
Installation Instructions / User's Manual
TSTAT0404 and TSTAT0405
3 HEAT – 2 COOL
Menu Driven Display
482 01 5300 01 November 2006

Advertisement

loading

Summary of Contents for ICP TSTAT0404

  • Page 1 997-060180-3 Installation Instructions / User’s Manual TSTAT0404 and TSTAT0405 3 HEAT – 2 COOL Menu Driven Display 482 01 5300 01 November 2006...
  • Page 2 HOLD SETTING -- Vacation & Permanent This section describes the HOLD functions. You can program the thermostat to hold the temperature for a period of time. If you want to hold the temperature for a few hours or a few weeks, your thermostat can accommodate your schedule.
  • Page 3 If you selected TEMP ADJUST ONLY, you will only be able to adjust BACKLIGHT ON TIME the set point temperature. Any other operation will require the pin This thermostat has a two color backlight feature. Anytime a button is number to unlock the thermostat. pressed, the blue backlight stays on for a certain amount of time.
  • Page 4 want the fan to be energized. Ranges are OFF, or 5-20 minutes in 5 PROGRAM SETTINGS minute increments. MENU → SETTINGS → PROGRAM SETTINGS After entering this time and pressing the center button ■, the next screen is the amount of time the fan is OFF. Ranges are SMART RECOVERY 0 minutes, or 5-40 minutes in 5 minute INTERMITTENT FAN...
  • Page 5: Advanced Features

    GENERIC WIRING DIAGRAMS INSTALLER ADVANCED FEATURES INFORMATION / 1 STAGE FURNACE / FAN COIL WITH 1 STAGE SAFETY CONSIDERATIONS Improper wiring or installation may damage thermostat. Wiring must conform to local and national electrical codes WARNING: Before installing thermostat, turn off all power to unit. There may be more than one power disconnect.
  • Page 6 VARIABLE SPEED INDOOR WITH 2 STAGE AC VARIABLE SPEED FURNACE WITH 2 STAGE HP (“DUAL FUEL”) VARIABLE SPEED INDOOR WITH 2 STAGE HP THERMOSTAT CONNECTIONS C - 24V Common for Control Circuit W2 – 2 Stage Heat R – 24V Supply for Control Circuit W1 –...
  • Page 7 Air Cleaner - Cumulative Run Time default is 0 hours (OFF) and Calendar Time is OFF. Values can range from 400-3600 hours for Cumulative Run Time (in 100 hour increments), or Calendar Time can be set to OFF, or 3-24 months (in 3 month increments). INPUT DEALER INFO Contractors are able to input Brand Name, Model Number, Contractor Name, and Contractor Phone number into these screens.