Installing The Blind Spot Aid - Dometic MagicWatch MWE 4004 Installation And Operating Manual

Blind spot assistant
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
MWE4004
6.2
Determining the place of installation for the sensors
See fig. 3 to fig. 5
I
NOTE
The sensors must be correctly aligned for the device to work properly.
If they point to the ground, irregularities and bumps on the surface may
be interpreted as obstacles. If they point too far up, obstacles will not be
detected at all.
Note the following during installation:
The area around the sensors must be free from other objects.
The distance from the sensors to the ground when horizontally aligned should be
at least 45 cm and a maximum of 60 cm (fig. 3).
Note that the installation angle depends on the installation height.
Select the right sensor holder and the appropriate drill diameter by consulting
the table in fig. 3.
Supplementary to fig. 5
➤ Observe the intervals between sensors.
I
NOTE
You can also distribute the sensors as shown in alternative B and C.
7

Installing the blind spot aid

See fig. 6 to fig. 0
Supplementary to fig.
A
NOTICE! Risk of malfunction!
Align the sensor holders so that the fastening lugs are horizontal. Other-
wise there is no guarantee the blind spot assistant will function correctly.
➤ Push the sensor holders into the holes until they lock into place.
EN
?
Installing the blind spot aid
7