ACD CAL 2000 LT Instruction Manual

Gas generator, release i

Advertisement

Quick Links

ACD
ACD
Advanced Calibration Designs, Inc.
Cal 2000 LT
Cal 2000 LT
Gas Generator
Release I
Advanced Calibration Designs, Inc.
2024 W. McMillan Street
Tucson, Arizona 85705
U.S.A.
Telephone: (520) 290-2855
Fax: (520) 290-2860
E-mail: ACD@auptag.com
INSTRUCTION MANUAL
Revision - 040525
www.goacd.com

Advertisement

loading

Summary of Contents for ACD CAL 2000 LT

  • Page 1 Advanced Calibration Designs, Inc. Cal 2000 LT Cal 2000 LT Gas Generator Release I Advanced Calibration Designs, Inc. 2024 W. McMillan Street Tucson, Arizona 85705 • U.S.A. Telephone: (520) 290-2855 • Fax: (520) 290-2860 E-mail: ACD@auptag.com INSTRUCTION MANUAL Revision - 040525...
  • Page 2 Air Flow Rate ..............0.5 or 1.0 LPM TABLE OF CONTENTS (flowrate must be specified when ordering CAL 2000 LT) Warm-up time (to 90%)....Approximately 5 minutes L x W x H......8.5 x 4.25 x 3.0” (21.6 x 10.8 x 7.6 cm) Weight..............3 lbs.
  • Page 3 700-0600-03 Pump, Low Flow Rotary Vane, 6 VDC WARNING: 715-0403-0X 3 Foot Hose w/connector, low flow, 1/4" OD 715-0405-0X 5 Foot Hose w/connector, low flow, This instrument generates calibration gas for toxic 1/4" OD gas detectors. The instruction manual should be read and understood prior to operation of the 730-0615-00 Hard-body, Water Resistant, Padded...
  • Page 4 510-2000-LT Chlorine Cell amount of air is supplied continuously to the cell. Each cell has a built-in memory chip that tells the Cal 2000 LT instru- 510-2050-LT Hydrogen Sulfide Cell ment what type and concentration of gas is to be generated and how much cell life is remaining.
  • Page 5 The following is a listing of the available electrochemical ‘plunger feet’ on the bottom of the instrument. Once all of Cal 2000 LT cells and their standard warranty when the plungers have been pulled out, the bottom cover is sim- installed in equipment manufactured and supplied by ply removed from the instrument.
  • Page 6 The Cal 2000 LT has a liquid crystal display (LCD) located on without our prior approval. the front of the instrument. This display is protected by a thin, clear plastic cover that is part of the front label and may be Advanced Calibration Designs, Inc.'s obligation under this...
  • Page 7 The Cal 2000 LT has a built-in mass flow sensor that mea- ing cell. sures the flow rate of the instrument. This information is used to control the pump to provide the desired flow-rate.
  • Page 8 AC Adapter There are two common causes for the unit to not power The Cal 2000 LT may also be operated from an AC adapter. up when the POWER switch is pressed for three sec- The AC adapter converts the AC voltage supplied from the onds.
  • Page 9 Normal Operation Maintenance To start the generator, press and hold the POWER switch, The electrochemical cells of the CAL 2000 LT require located in the middle left front of the instrument, until the periodic maintenance to provide optimum performance. It is display reads A.
  • Page 10 Flow-Rate Select Option Immediately after the flow rate screen appears, the ppm The CAL 2000 LT is shipped from the factory set at either 0.5 screen appears. LPM or 1.0 LPM depending on what was specified when the unit was ordered.
  • Page 11 Once the flow and concentration have been displayed, the instrument will enter the stabilization period and the display When you are finished generating gas and wish to turn off will alternate between the following three screens: the instrument, press and hold the POWER switch until the purge screen is displayed.