ENGLISH
periods, outside of these normal temperature
ranges may affect production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm clearance at rear and sides for
proper air circulation and ease of maintenance
and/or service should they be required. Allow
60 cm clearance on top to allow for removal of
the Auger.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the icemaker
or in front of the Louver.
7. This icemaker will not work at subfreezing
temperatures. To prevent damage to the water
supply line, drain the icemaker when air
temperature is below zero (see "II. 2.
PREPARING THE ICEMAKER FOR LONG
STORAGE" in the instruction manual).
8. The noise from this icemaker is 55 dB or less.

3. INSTALLATION

* Incorrect installation can cause harm to people,
animals or things, for which the manufacturer cannot
be held responsible.
1) Fully screw in the four legs provided (bin accessory)
into the Storage Bin underside. See Fig. 3.
Bottom Plate
Adjustable Legs
2) Position the Storage Bin in the selected permanent
site.
3) Place the icemaker on top of the Storage Bin by
holding the bottom.
4) Secure the icemaker to the Storage Bin, by using
the two mounting brackets and two bolts provided.
See Fig. 4.
Bolt
5) Seal the seam between the icemaker and the
Storage Bin with food grade sealant.
6) Refit the Side Panels in their correct position.
7) Adjust the four legs on the bottom (adjustable from
0 to 25.4 mm) to have the icemaker perfectly
horizontal. Use the spirit level. See Fig. 5.

4. ELECTRICAL CONNECTIONS

THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Remove the plug from the mains socket before
any maintenance, repairs or cleaning is
Fig. 3
undertaken.
* This icemaker should not be installed:
a) Where the power supply is not within the range
of 220 - 240V.
b) Where the icemaker cannot be connected directly
2