Powered tdcontrollers digital patching unit digital meters unit (140 pages)
Summary of Contents for Nexo GEO S12 Series
Page 1
GEO S12 Series Geo S1210 & Geo S1230 Tangent Array Modules Geo S12 Analog TD Controller User Manual GEO S12 Series User Manual V1.02 Date: 07/03/2008...
Page 2
A comprehensive understanding of GEO theory, tangent arrays, and specific features of the GEO S12 Series will help you to operate your system at its full potential.
Page 3
Page 3/112 NTRODUCTION SAFETY ISSUES IMPORTANT NOTICE CONCERNING HIGH SOUND PRESSURE LEVELS Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time.
3.2.1 NXAMP connectors ..................16 3.2.2 GEO S12s and NXAMP recommended configurations........17 GEO S12 Setups on NEXO TD Controllers ..............18 Digital NX242-ES4 and NXAMP TDControllers ............18 Analogue GEOS12 TDController ................19 Connection diagrams ....................19 GEO S12 & RS15 with GEOS12 TDController (Mono Omni Mode) ......19 GEO S12 / NX242-ES4 (4 channels passive mode)..........20...
Page 5
Page 5/112 NTRODUCTION GEOSoft2........................28 Configurable Directivity Device................... 29 Installing & removing GEO’s Configurable Directivity flanges ......... 29 When & where to use Configurable Directivity flanges ..........30 GEO S12 hardware setup procedure ................31 SAFETY FIRST ....................... 31 8.1.1 Flown Systems Safety..................31 8.1.2 Ground Stacking Safety ...................
Page 6
Front Panel .......................72 9.4.3 Rear Panel......................73 TDcontroller REFERENCE GUIDE................74 9.5.1 Linear section ....................74 9.5.2 Servo Control section ....................74 NEXO NX242-ES4 Digital Controller for GEO S12 ..........76 10.1 NX242 Proprietary Functions...................76 10.1.1 Upgradable Firmware ..................76 10.1.2 EQ & Filtering ....................76 10.1.3...
Page 7
Page 7/112 NTRODUCTION 10.2 Trouble shooting...................... 78 10.2.1 Operation of Multiple TDcontrollers output channels........78 10.2.2 Amplifier Power (MENU 2.7) ................78 10.2.3 Amplifier Gain (MENU 2.6) ................78 10.2.4 Gains........................ 78 10.2.5 Delays ......................79 10.2.6 Reversed Cardioid Pattern ................79 10.2.7 Using the wrong NX242 setups for a given cabinet..........
Page 8
NX242 TDcontroller with NX-Tension Card ............107 13.6.1 Specifications ....................107 13.6.2 Front and Rear Panel view ................107 13.6.3 Block Diagram ....................108 GEO S12 Series Parts & Accessories List ............109 14.1 Modules & Control Electronics List ................109 14.2 Accessories List.....................109 USER NOTES ......................111...
Page 9/112 NTRODUCTION NTRODUCTION Thank you for selecting a NEXO GEO S12 Series Tangent Array System. This manual is intended to provide you with necessary and useful information about your GEO S12 System, which includes the following products: • GEO S1230 is a 30° Tangent Array Module.
Page 10
Page 10/112 NTRODUCTION As for all NEXO systems, GEO S12s are controlled, powered and monitored by dedicated NEXO TDControllers: • GEO S12 TDController is based on PS analogue TDController design, and provides full control for RS15 subwoofer in omnidirectional mode associated to Geo S12. It has 2 analogue inputs (Left and Right) and 3 analogue outputs (RS15 Mono Omni, GeoS12 Left and GeoS12 Right);...
Page 11
• GEOSoft2 Array Design Software assists in the design and implementation of vertical tangent GEO arrays. Please consult the NEXO web site (www.NEXO.fr or www.NEXO-sa.com) for the latest software releases. Please devote your time and attention to reading this manual. A comprehensive understanding of GEO theory, tangent arrays and specific features of GEO S12 will help you to operate your system at its full potential.
2.1.3 Cabling NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is compatible with all the cabinets, and there is no possible confusion between LF, MF and HF sections. Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to the load resistance and the cable length.
GEO S12 G Page 13/112 ENERAL NSTRUCTIONS 2.1.4 Example: • GEO S12 has a 16 Ohms nominal impedance in passive mode, so 4x Geo S12 wired in parallel will present a 16/4 = 4 Ohm load impedance. The maximum acceptable 2x2.5 mm (AWG #12) cable length L for such a cluster is 10 meters.
MPLIFIER ELECTION FOR USE WITH NEXO recommends high power amplifiers in all cases. Budget constraints are the only reason to select lower power amplifiers. A lower power amplifier will not reduce the chances of driver damage due to over-excursion, and may actually increase the risk of thermal damage due to sustained clipping. If an incident occurs on an installation without protection, the fact that amplifiers only generating half their rated output power (-3dB) are used will not change anything in respect of possible damage.
Page 15
Remember that constant sensitivity settings will give a different gain value when the amplifier power is different. NEXO recommends low gain amplifiers: +26dB is recommended, as it is at the same time adequately low and quite common amongst amplifier manufacturers. This gain setting improves signal to noise ratio and allows all preceding electronic equipment, including the NX242 TDcontroller or GEO S12 TDController, to operate at optimum level.
These functions are not adapted to specific system requirements and may interfere with the complex protection algorithms used in the NX242. NEXO do not advise using other protection systems in conjunction with the NX242 and they should be disabled.
GEO S12 Page 17/112 MPLIFIER ELECTION FOR USE WITH Figure below shows connectors implementation on the rear panel. 3.2.2 GEO S12s and NXAMP recommended configurations Passive Mode Active Mode 3 GEO S12 1 channel of NXAMP4x1 in Bridge Stereo Mode 2 channels of NXAMP4x1 in Bridge Stereo Mode 1 channel of NXAMP4x4 in 4 channels mode 2 channels of NXAMP4x4 in 4 channels mode...
ETUPS ON ONTROLLERS 4.1 Digital NX242-ES4 and NXAMP TDControllers At GEO S12 User Manual current version printing time, 38 setups combining GEO S12s with NEXO subwoofers are available in NX242 / NXAMP load 2.45. Please consult www.nexo-sa.com for upgrade releases.
Page 19/112 ONNECTION DIAGRAMS 4.2 Analogue GEOS12 TDController GEO S12 TDController parameters have been optimized for 1 x RS15 (omni mode, mono) used in conjunction with 2 x GEO S1210’s or 2 Geo x S1230’s (mono or stereo). ONNECTION DIAGRAMS 5.1 GEO S12 &...
Geosoft2 installation package includes all GEO User Manuals, Structural Analysis Reports and Certificates PDF files (which can be found in the last section of User Manuals). Geosoft2 is a freeware downloadable on www.nexo-sa.com. Please check our website periodically for upgrades.
Remove the three TORX (5x25) screws per flange on each side of the GEO Waveguide (drawings below); • Install the 120° flanges with the six TORX screws • Re-install the grid, being careful that the NEXO logo must be on the 12” loudspeaker side. REMOVING THE GRILL REMOVING THE SCREWS REPLACING THE FLANGES...
Page 30/112 ONFIGURABLE IRECTIVITY EVICE 7.2 When & where to use Configurable Directivity flanges The diagrams show audience area coverage for a stereo system. While the GEO cluster will deliver even SPL from the front to the rear of this audience area, there are “holes” near the front in the centre and at the outside edges.
However, user must always apply his or her knowledge, experience and common sense. If in any doubt, seek advice from your supplier or NEXO agent. This manual offers guidance only for GEO S12 loudspeaker systems. References in this manual to other rigging equipment such as motor hoists, steels, shackles etc.
• The GEO S12 Rigging System requires regular inspection and testing by a competent test centre. NEXO recommend that the system is load tested and certified annually or more frequently if local regulations require. •...
HARDWARE SETUP PROCEDURE 8.1.3 Contacts Correct training is fundamental to safe practise when working with loudspeakers flying systems. NEXO recommend that users contact local industry associations for information on specialist course. Information for International training agencies can be obtained by contacting either:...
Page 34/112 GEO S12 HARDWARE SETUP PROCEDURE 8.2 General Description GEO S1230 GEO S1210 GEO S1230 and GEO S1210 incorporate two connecting plates (one per side) on which a comprehensive range of accessories can be mounted. Oblong holes for Touring Applications Accessories Tapped holes for Fixed Installation Accessories GEO S12 CONNECTING PLATES There are two families of accessories:...
Never use other accessories – including push-pins - when assembling GEO S12 cabinets than the ones provided by NEXO: NEXO will decline responsibility over the entire GEO S12 accessory range if any component is purchased from different supplier. WARNING 2...
In order to prevent screws from getting loose in fixed installations, use blocking liquid LOCTITE 243 or equivalent for all screws used with GEO S12 fixed installation accessories. LOCTITE 243 is available at NEXO or at your local distributor upon request. GEOS12-FBUMPER GEOS12-UBRK GEOS12-LBRK GEOS12-ABRK...
Page 38/112 GEO S12 HARDWARE SETUP PROCEDURE 8.3.2 Single GEO S12 rigidly mounted on a wall or a ceiling (vertical or horizontal) Required items • 1 x GEOS12-UBRK (allows all angles to be implemented) • 4 x 12mm diameter screws (not provided) IMPORTANT Ensure that the surface –...
GEO S12 Page 39/112 HARDWARE SETUP PROCEDURE 8.3.3 Single GEO S12 cable mounted on a wall or a ceiling (vertical or horizontal) Required items • 1 or 2 x GEOS12-LBRK (allows cable suspension, holes for cable suspension are 10mm diameter); •...
Page 40/112 GEO S12 HARDWARE SETUP PROCEDURE 8.3.4 GEO S12 vertical array rigidly mounted on a ceiling Required items • 1 x GEOS12-FBUMPER (allows +/-5° bumper tilt when installed below a flat surface; if higher bumper tilt is required, surface will have to be defined accordingly) ; •...
Page 41
GEO S12 Page 41/112 HARDWARE SETUP PROCEDURE • (7) Flip the cluster upside down to access connector plates located on the down side; • (8) Repeat all above steps from #2 to #6; • • (9) Position the GEOS12-FBUMPER bumper to required angle position and use the four shoulder screws from GEOS12-FBUMPER kit to connect it the bumper to the top cabinet;...
GEO S12 Page 43/112 HARDWARE SETUP PROCEDURE 8.3.6 GEO S12 horizontal array rigidly mounted on a ceiling Required items • 2 x GEO S12-ABRK (allows rigid ceiling suspension for horizontal arrays) • (N-1) x GEOS12-ANPL for a N x GEO S12 array (ANPL1 ranges from 0.2° to 3.15°, ANPL2 ranges from 5°...
Page 44
Page 44/112 GEO S12 HARDWARE SETUP PROCEDURE • (7) Flip the cluster upside down to access connector plates located on the down side; • (8) Repeat all above steps from #2 to #6; • (9) Position the two “U” brackets from GEOS12-ABRK kits on the outer cabinets next the angle plates, and tight them to the cabinets using the shoulder screws provided with these kits, •...
GEO S12 Page 45/112 HARDWARE SETUP PROCEDURE 8.3.7 GEO S12 horizontal array cable mounted on a ceiling Required items • 2 x GEO S12-LBRK (allows cable suspension for horizontal arrays, holes for cable suspension are 10mm diameter); • (N-1) x GEOS12-ANPL for a N x GEO S12 array (ANPL1 ranges from 0.2° to 3.15°, ANPL2 ranges from 5°...
R > H IMPORTANT (RS15 POLE STAND) - NEXO STDPS pole stand only should be used for mounting on top of NEXO RS15 - If 2 RS15s are to be stacked below GEO S12s pole mounted, they should be connected together through use of RS15 rigging plates;...
GEO S12 Page 49/112 HARDWARE SETUP PROCEDURE 8.4.3 Single GEO S12 flown vertically Required items • 1 x Flying Bar for single vertical GEO S12 (GEOS12-TTC-V2) • 1 x Lifting Ring (GEOS12-XHBRK) • Or 1 x Truss hook (GEOS12-TCBRK-V2) IMPORTANT Ensure that truss suspension point is strong enough to hold GEO S12 weight.
Page 50/112 GEO S12 HARDWARE SETUP PROCEDURE 8.4.4 Single GEO S12 flown horizontally Required items • 1 x “U” Bracket for single horizontal GEO S12 (GEOS12-SSBRK-V2) • 1 x Lifting Ring (GEOS12-XHBRK) • Or 1 x Truss hook (GEOS12-TCBRK-V2) IMPORTANT Ensure that suspension point is strong enough to hold GEO S12 weight.
R > H IMPORTANT (RS15 POLE STAND) - NEXO STDPS pole stand only should be used for mounting on top of NEXO RS15 - If 2 RS15s are to be stacked below GEO S12s pole mounted, they should be connected together through use of RS15 rigging plates;...
GEO S12 Page 55/112 HARDWARE SETUP PROCEDURE 8.4.6 Two GEO S12 flown horizontally Required items • 1 x “U” Bracket for two GEO S12s (GEOS12-PSBRK-V2) • 1 x Lifting Ring (GEOS12-XHBRK) • Or 1 x Truss hook (GEOS12-TCBRK-V2) IMPORTANT Ensure that suspension point is strong enough to hold two GEO S12s weight. Procedure •...
Page 56/112 GEO S12 HARDWARE SETUP PROCEDURE 8.4.7 Two or more GEO S12 flown vertically Required items • N Pair of Rigging Plates (GEOS12-XBOW-V2) for N cabinets; • 1 lifting ring (GEOS12-XHBRK) every two GEO S12; • 4xN Quick release pins for N cabinets; •...
Page 57
IMPORTANT GEO S12 can be flown “Up” or “Down” : - “Up” means Nexo logo on front grid is at the top; - “Down” means Nexo logo on front grid is at the bottom. GEO S12 can be connected “Up” or “Down” by simply flipping the cabinets.
Page 58
Page 58/112 GEO S12 HARDWARE SETUP PROCEDURE • Lift and position assembly, connect lifting rings to suspension points with sling and shackle; • Secure assembly with secondary safety steel. IMPORTANT The requirements for secondary safety systems vary with territories. However, the secondary safety steel MUST have a SWL equivalent or greater than that of the rigging system.
GEO S12 Page 59/112 HARDWARE SETUP PROCEDURE 8.4.8 Three or more GEO S12 flown horizontally Required items • 1 x Bumper (GEOS12-BUMPER); • N Pair of Rigging Plates (GEOS12-XBOW-V2) for N cabinets; • 4xN Quick release pins for N cabinets; •...
Page 60
Page 60/112 GEO S12 HARDWARE SETUP PROCEDURE To facilitate flying operation, an optional link bar with oblong holes (GEOS12-TLB, pair of link bars provided with two 8x20 quick release pin) is available in the GEO S12 accessory range. GEO S12 X-BOW OPTIONAL GEOS12-TLB LINK BAR To install GEOS12-TLB, remove the standard link as well as nut, screw and washers.
Page 61
IMPORTANT GEO S12 can be flown “Left” or “Right” : - “Left” means Nexo logo on front grid is left as seen from front; - “Right” means Nexo logo on front grid is right as seen from front. GEO S12 can be connected to bumper “Left” or “Right” by simply flipping the cabinets.
Page 62
Page 62/112 GEO S12 HARDWARE SETUP PROCEDURE IMPORTANT Ensure angle settings are identical on both sides of the cabinets. Ensure that safety pins are properly locked into GEO S12s connecting panels. Ensure that all quick release pins are properly locked into their position. •...
GEO S12 Page 63/112 HARDWARE SETUP PROCEDURE 8.4.9 Ground stacked GEO S1210 Required items • N Pair of Rigging Plates (GEOS12-XBOW-V2) for N cabinets; • 1 ground stack device (GEOS12-GSTK); • 4xN Quick release pins for N cabinets; IMPORTANT - Ground stack device GEOS12-GSTK is rated for a maximum of 6 GEO S1210s in any inter cabinet angle configuration, provided this device is assembled according to below rules.
Page 64
Page 64/112 GEO S12 HARDWARE SETUP PROCEDURE GEO S12 ground stack device description GEOS12-GSTK ground stack device includes: • two supporting beams, which support assembly weight; • two connecting beam, which allow connection of the beams to the first cabinet; •...
Page 65
GEO S12 Page 65/112 HARDWARE SETUP PROCEDURE • Insert GEOS12-XBOW-V2 into connecting plates of both sides GEO S12s; • Lock safety pins into GEO S12s connecting plate; IMPORTANT Ensure that safety pins are properly locked into GEO S12s connecting panels. •...
• After cleaning, the rigging system must be treated with a suitable lubricant to prevent rusting. NEXO recommends the use of Scottoil FS365 which is a water-based lubricant with a mixture of machine oil, surfactant and anti-rust treatment.
FCC Rules, any changes or modifications to this equipment not expressly approved by been dropped. NEXO S.A. may cause, harmful interference and void the FCC authorization to operate this equipment.
Mains Power NEXO TDcontrollers don’t provide a mean to switch off the unit from the front panel. As they are intended to be rack mounted the back panel is not accessible during use. Therefore it is left to the user to provide a disconnection mean readily operable.
The emission (this word describes all types of electromagnetic noise radiated by the equipment) requirements which have been applied to Nexo’s TDcontrollers are the stringent requirements of the ”Commercial and light industrial environment” of the product family EMC standard for emission.
NEXO A S12TD C Page 71/112 NALOGUE ONTROLLER degradation of output noise. We recommend that the sources and loads you use have the same desirable characteristics. It is sometimes claimed that connecting cable shield at both ends creates ground looS12, and that the current flowing in such looS12 will produce noise.
Page 72/112 NEXO A S12TD C NALOGUE ONTROLLER • High CMRR input stage and High current drive output • Compensation of power compression effects on the system response curve. The Analogue TDcontroller is designed to be inserted between the Audio source (console, preamplifier, etc.) and the power amplifier.
NEXO A S12TD C Page 73/112 NALOGUE ONTROLLER To set the peak limiter to the correct value, either turn the trimmer clockwise until the red LED lights at the same time as the amp’s clipping LED, or use the graduation (power value given for 8Ωload).
Page 74/112 NEXO A S12TD C NALOGUE ONTROLLER Always ensure that your TDcontroller is disconnected from main before opening the unit. Remove the 3 screws fastening the top panel. The ST1 jumper is located near the Input XLR. The PIN1 being the PIN closest of the Input XLR.
Page 75
NEXO A S12TD C Page 75/112 NALOGUE ONTROLLER • The other elements work selectively as dynamic equalizers (LF-VCEQ & HF-VCEQ). Depending on the nature and origin of the servo signals, either one or the 3 combined elements is used to process the Audio signal. This feature allows more efficient processing while reducing audible effects.
10.1.1 Upgradable Firmware NEXO releases regular firmware updates. Each new release is the result of our ongoing R&D program combined with user feedback from the field. New firmware releases can include new setups for different combinations of NEXO full range loudspeakers and subwoofers, improvements to existing setups, and new software functions.
NEXO NX242-ES4 D GEO S12 Page 77/112 IGITAL ONTROLLER FOR 10.1.3 Protection VCAs and VCEQs Each channel has its own simulation and protection process. Each audio channel contains a combination of controlled gain stages (let's call them VCAs as in analogue circuitry). These VCAs are...
The NX242 has been designed to be user-friendly. However with highly technical systems such as GEO S12, incorrect adjustment of the NX242 can lower the quality & safety of your system. Listed below are the most common errors encountered by NEXO Technical Support. 10.2.1 Operation of Multiple TDcontrollers output channels Typically, GEO S12 systems require multiple NX242’s output channels per side.
10.2.7 Using the wrong NX242 setups for a given cabinet Each NX242 setup is tailored for a certain NEXO loudspeaker. Using the wrong setup will create safety and quality problems. Always check that every cabinet in your system is being driven by the correct NX242 setup.
Cluster design must be done with Geosoft2, which provides very intuitive and fast method to determine all cluster geometry parameters in relation to venue where cluster is implemented. IMPORTANT Geosoft2 is a freeware downloadable on www.nexo-sa.com. Please check our website periodically for upgrades. Never install a GEO S12 cluster without checking its acoustical performances and mechanical safety in Geosoft2 prior to installation.
& safety of the system (mostly time alignment). At NEXO, great care is taken to design optimum phase alignment from one octave above to one octave below the crossover frequency point. By doing so, drivers are working perfectly together and providing the best efficiency possible.
Page 82
Angle (in radians)=3.142 x Angle (in degrees)/180 • Computer – Laptop or Desktop PC running Windows XP with the current version of NEXO GeoSoft2 installed. It is not possible to configure a Geo tangent array properly without using GeoSoft2. Note that, when GeoSoft2 designs are prepared prior to arrival at the venue, it is often necessary to modify or update the design to accommodate special circumstances.
GEO S12 – RS15 / CD18/S2/GEOSUB S Page 83/112 YSTEM HECK 12 GEO S12 – RS15 / CD18/S2/GEOSUB S YSTEM HECK It is essential to execute all these check steps prior to perform a sound check on the “front end” to the system.
Page 84/112 GEO S12 – RS15 / CD18/S2/GEOSUB S YSTEM HECK 12.4 Are the speakers properly connected and angled ? • Attach the first series of modules to the bumper. • Before flying, verify that all channels of all modules are functioning properly. •...
Electronic controller The NEXO TDcontrollers presets are precisely matched to the GEO S12 Series cabinets and include sophisticated protection. Using GEO S12 Series cabinets without a properly connected NEXO TDcontrollers will result in poor sound quality and can damage components.
Electronic controller The NEXO TDcontrollers presets are precisely matched to the GEO S12 Series cabinets and include sophisticated protection. Using GEO S12 Series cabinets without a properly connected NEXO TDcontrollers will result in poor sound quality and can damage components.
Page 97/112 ECHNICAL PECIFICATIONS 13.3.9 Ground Stacking Device for up to 6 GEO S1210 Parts #GEOS12-GSTK In Service Equipment Storage Pattern Dimensions 1030 1035 Weight (kit) 26.5 kg / 58.4 Lbs...
Page 103/112 ECHNICAL PECIFICATIONS 13.4.6 “L” Bracket for cable suspension Parts #GEOS12-LBRK WARNING : Screws must be secured using Loctite 243 Dimensions Weight (kit) 1.75 kg / 3.86 Lbs...
Page 104/112 ECHNICAL PECIFICATIONS 13.4.7 “U” Bracket for rigid suspension Parts #GEOS12-ABRK WARNING : Screws must be secured using Loctite 243 Dimensions Weight (kit) 1.75 kg / 3.86 Lbs...
Speaker Protection yellow LED for each channel Individual Mute/Solo buttons and red LED for each channel Amp. Sense & Peak (green & red) LED’s for each channel FLASH EPROM Software updates/upgrades, new system setups, available on www.nexo- sa.com Rear Panel RS232 connector for serial com...
GEO S12 S & A Page 109/112 ERIES ARTS CCESSORIES 14 GEO S12 S & A ERIES ARTS CCESSORIES 14.1 Modules & Control Electronics List MODEL DRAWING DESCRIPTION GEO S1230 GEO S1230 Module GEO S1210 GEO S1210 Module NX 242–ES4 Digital TDcontroller NXAMP4x1 Digital Powered Controller 4x1300W...
Page 110
Page 110/112 GEO S12 S & A ERIES ARTS CCESSORIES MODEL DRAWING DESCRIPTION GEOS12-TTC-V2 Truss hook for single vertical GEO S12 “U” Bracket for single horizontal GEO S12 on tripod or GEOS12-SSBRK-V2 on truss hook or lifting ring U” Bracket for two GEO S12 on subwoofer pole stand GEOS12-PSBRK-V2 or on truss hook or on lifting ring GEOS12-GSTK...
Need help?
Do you have a question about the GEO S12 Series and is the answer not in the manual?
Questions and answers