Carrier Aquazone 50PTH036 Installation, Start-Up And Service Instructions Manual page 11

Two-stage water source heat pumps with puron refrigerant
Table of Contents

Advertisement

5
4
2
21
16
1
1
— Compressor Contactor
2
— Emergency Relay (Option)
3
— Second Stage Relay
4
— Hot Gas Reheat Relay (Option)
5
— Cooling Relay
6
— Complete C Control
7
— Terminal Block Low-Voltage
8
— Auxiliary Relay (Option)
9
— Transformer
10
— Capacitor
16
— Comfort Alert Module (Option)
21
— Ground Lug
Fig. 8 — Single-Phase Unit
Control Box Layout
UNIT SIZE COMPRESSOR
8733902168
208/230-1-60
8733801381
265/277-1-60
50PT024
8733801385
208/230-3-60
8733801392
8733902169
208/230-1-60
8733801382
265/277-1-60
50PT036
8733801386
208/230-3-60
8733903844
8733902170
208/230-1-60
50PT048
8733801387
208/230-3-60
8733801393
8733902171
208/230-1-60
50PT060
8733801388
208/230-3-60
8733801394
8733902172
208/230-1-60
50PT070
8733801389
208/230-3-60
8733801395
LEGEND
ECM
— Electronically Commutated Motor
FLA
— Full Load Amps
HACR — Heating, Air Conditioning and Refrigeration
LRA
— Locked Rotor Amps
MAX
— Maximum
MIN
— Minimum
RLA
— Rated Load Amps
3
7
10
Table 4 — 50PTH,PTV Blower Motor Electrical Data
COMPRESSOR
RATED
VOLTAGE
VOLTAGE
MIN/MAX
v-ph-Hz
QTY
197/253
1
1
197/253
1
460-3-60
1
197/253
1
1
197/253
1
460-3-60
-
1
197/253
1
197/253
1
460-3-60
-
1
197/253
1
197/253
1
460-3-60
-
1
197/253
1
197/253
1
460-3-60
-
1
6
4
13
14
8
21
12
9
1
2
3
4
5
6
7
8
9
12
13
14
15
21
TOTAL UNIT CONST TORQUE
MOTOR (STANDARD)
MIN CIRCUIT
RLA
LRA
FLA
AMPS
11.7
58.3
2.8
17.4
9.1
54.0
2.6
14.0
6.5
55.4
2.8
10.9
3.5
28.0
2.1
6.4
15.3
83.0
6.0
25.1
13.0
72.0
4.9
21.2
11.6
73.0
6.0
20.5
5.7
38.0
3.2
10.4
21.2
104.0
6.0
32.4
14.0
83.1
6.0
23.5
6.4
41.0
3.2
11.3
27.1
152.9
7.6
41.5
16.5
110.0
7.6
28.3
7.2
52.0
4.0
13.1
29.7
179.2
7.6
44.7
17.6
136.0
7.6
29.6
8.5
66.1
4.0
14.6
11
3
5
7
2
1
15
— Compressor Contactor
— Emergency Relay (Option)
— Second Stage Relay
— Hot Gas Reheat Relay (Option)
— Cooling Relay
— Complete C Control
— Terminal Block Low-Voltage
— Auxiliary Relay (Option)
— Transformer
— Phase Monitor
— Fan Status Switch (Option)
— Pump Status Switch (Option)
— Terminal Block 460-v Units (Option)
— Ground Lug
Fig. 9 — Three-Phase Unit
Control Box Layout
TOTAL UNIT ECM CONST airflow
MOTOR (OPTION)
MAX FUSE/
MIN CIRCUIT
FLA
HACR
AMPS
25
2.8
17.4
20
2.6
14.0
15
2.8
10.9
15
2.6
6.9
35
6.8
25.9
30
5.5
21.8
30
6.8
21.3
15
5.5
12.6
50
6.8
33.2
35
6.8
24.3
15
5.5
13.5
60
9.1
43.0
40
9.1
29.8
20
6.9
16.0
70
9.1
46.2
45
9.1
31.1
20
6.9
17.5
6
8
9
MAX FUSE/
HACR
25
20
15
15
35
35
30
15
50
35
15
70
45
20
70
45
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents