Technical data
SCALANCE W761/W722/W721
Antenna connector
Frequency range
Electrical data
Power supply
Fusing
Current consumption
Power loss at 24 VDC
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Contaminant concentration
Degree of protection
Dimensions and weight
Dimensions
Weight
Installation options
Mean time between failure (MTBF)
44
Quantity
Design
Impedance
Supply voltage
Permitted range
Design
At 24 VDC / typical
At 24 VDC / typical
During operation with the rack instal‐
led horizontally / vertically
During storage
During transportation
During operation
During operation
IP code
W x H x D
Installation on a DIN rail
at 40 °C ambient temperature
1
R-SMA female
50 Ω nominal
2412 ... 2480 MHz
4920 ... 5875 MHz
24 VDC Safe Extra Low Voltage (SELV)
19.2 to 28.8 VDC
Terminal block, 3 terminals
2.5 A / 24 VDC
150 mA
3.6 W
0 ℃ to +55 ℃
-40 ℃ to +85 ℃
-40 ℃ to +85 ℃
≤ 95% at 25 °C, no condensation
≤ 2,000 m above sea level at max. 55 °C
ambient temperature
According to IEC 60721
IP20
50 x 114 x 74 mm
130 g
106.51 years
Operating Instructions, 09/2017, C79000-G8976-C322-08