Honeywell ICON 100 SERIES Installation Manual page 5

Refrigeration controller
Hide thumbs Also See for ICON 100 SERIES:
Table of Contents

Advertisement

E.
This controller is guaranteed by Honeywell to have a specific immunity
level, in compliance with CE regulations, against irradiated and
conducted electromagnetic disturbances. By irradiated electromagnetic
disturbances we recommend to screen the controller with a metal
screen connected to ground. To eliminate, or at least reduce
conducted disturbances, which not only could propagate through the
mains but also through the probes or the connected loads, carry out
the electrical wiring according to the indications given in this instruction
booklet. If necessary, use filters with suitable characteristics for specific
applications and for the detected type of disturbance.
F.
If the type of probe to be used will directly touch foodstuffs, make sure
that it is in compliance with the local sanitary and health regulations.
G.
The controller has no type of protection for the connected loads, so
these must be protected against short circuits, over-current or over-
voltage, excessive temperature, etc., by suitable protective means
(such as fuses, suitable thermo-magnetic circuit breakers, thermal
protections, etc.). At any rate, the electrical power lines that supply
both the controller and any other device connected to it, either directly
or through a transformer, must be manufactured in compliance with the
regulations in force.
ICON 100 SERIES INSTALLATION GUIDE
4
EN1B-0004UK07 R1003