Automatic squelch control
Table of Contents

Advertisement

Available languages

Available languages

SCAN
(long press)
Press and hold the UP or DN button (18) to
dot between the two channel digits flashes to indicate that the function is
active.
The scanning stops as soon as there is a busy channel. The scanning auto-
matically starts 3 seconds after the end of the transmission and if no key is
activated during 3 s. In
SCANNING
press the UP/DN buttons (18) on the microphone to change scan direction.
CB channel Scan
CB
mode press for ± 7 seconds or until a beep sounds to activate the CB
In
channel Scan.
Press PTT switch (17) to exit CB Channel Scan. The dot between the two
channel digits disappears from LCD.
WX channel Scan
WX
In
mode press for ± 3 seconds or until a beep sounds to activate the
WX channel Scan.
Press for 3 seconds the TALKBACK key (9) to exit WX Channel Scan. The dot
between the two channel digits disappears from LCD.
Note: The WX channel scan can run in the background while using the
mode.
A) DC-POWER TERMINAL (13,8 V)
B) ANTENNA CONNECTOR (SO-239)
C) JACK FOR EXTERNAL OPTIONAL SPEAKER (8 Ω, Ø 3.5 mm)
D) JACK FOR PA OPTIONAL SPEAKER (Public Address) (8 Ω,
Ø 3.5 mm)
E) JACK FOR OPTIONAL VOX MICROPHONE (8 Ω,Ø 2.5 mm)
C) MENU
The order of 11 functions is as described in this manual. However, the func-
tion displayed by entering the MENU will be the last function modified by
user.
The procedure is the same whatever the function is:
Press PUSH knob (6) for 3 seconds to
1.
Turn the rotary PUSH knob (6) or use UP/DN buttons (18) on the microphone
to
select
the menu.
2.
Press PUSH knob (6) to
validate.
on the display.
activate
the SCAN function. The
mode, turn the PUSH rotary knob (6) or
enter

MENU.

is displayed.
The parameter of the chosen function blinks
3.
Turn the rotary PUSH knob (6) or use UP/DN buttons (18) on the microphone
modify
to
the value of the parameter.
4.
New press PUSH knob (6) to
stops blinking and if the function has more than one parameter, the next
parameter blinks.
5.
If no key is pressed, the unit exits MENU after 10 seconds.
the display.
Note: UP/DN buttons (18) on the microphone have the same effect as the
rotation of the rotary PUSH knob (6). PTT switch (17)
and
exists
MENU.
disappears.
1) COLOR
This function allows to
Press PUSH knob (6) for 3 seconds to
1.
Turn the rotary PUSH knob (6) or use UP/DN buttons (18) on the microphone
to
select
the COLOR function.
2.
Press PUSH knob (6) to
3.
Turn the rotary PUSH knob (6) or use UP/DN buttons (11) on the microphone
to
select
the color. 7 available colors are displayed over and over :
CB
4.
New press PUSH knob (6) to
blinking. a) Go back to point 1 to
PTT switch (17) to
validate
5.
If no key is pressed, the unit
the display.
Default COLOR is
(red).
2) KEY BEEP
When the function is activated, a beep
changing the channel etc. "BP" appears on the display when the function
is active.
Press PUSH knob (6) for 3 seconds to
1.
Turn the rotary PUSH knob (6) or use UP/DN buttons (18) on the microphone
to
select
the KEyBEEP function.
2.
Press PUSH knob (6) to
3.
Turn the rotary PUSH knob (6) or use UP/DN buttons (18) on the microphone
to
activate
On /
deactivate
4.
New press PUSH knob (6) to validate. The parameter stops blinking. a) Go
back to point 1 to
adjust
validate
exit
MENU.
and
10
validate
the chosen value. The parameter
validates
choose
the backlight color of the LCD.
enter
MENU.
is displayed.
validate.
The current color blinks on LCD.
validate
the chosen color. The color stops
adjust
another function or b) Press the
exit
MENU.
and
disappears in the display.
exits
MENU after 10 seconds,
sounds
when a key is pressed, by
enter
MENU.
is displayed.
validate.
The current status blinks on LCD.
Of the function.
another function or b) Press the PTT switch (17) to
disappears.
disappears from
the last setting
disappears in

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents