Type Selection And Technical Data - Procentec ProfiHub F1 User Manual

Table of Contents

Advertisement

8.

Type selection and technical data

Type
Order no.
Fiber connector
Fiber
Optical budget
Transmission path
Wavelength
Transmission rate max.
Transmission
Operation Mode
Load
Cable Length
Connector
Control - LED's
Operating voltage
Current consumption
Potential separation
ProfiHub F1 User Manual v1.0.1 | September 2018 | ©PROCENTEC
13-MM-ST
123-022MM01-ST
ST
Multi mode
62,5 (50) /125µm
13dB
5 km
(2 dB/km)
1310 nm
12MBit/s
Half duplex
RS485 ↔ Fiber Optic LWL : < 3 TBit
switchable termination: open or characteristic impedance (Rw + Rpd + Rpu)
1.200m (9,6 – 187,5KBit/s), 400m (500KBit/s), 200m (1.5MBit/s) 100m (3MBit/s –
12MBit/s)
Cable Length according to PROFIBUS User Organization
9-pin female Sub-D and 6-pin connection terminal
Power supply (green) / Failure (red) / Data receive (green) / Status (red) / Fiber view (red,
yellow, green)
12-30 VDC, other voltages on request
200 mA
500 VDC (24 VDC → RS-485)
/
Tx ↔ Rx : 11 TBit
13/26