1. GENERAL DESCRIPTION
Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller, suitable for
temperature monitoring in a walk-in cooler or freezer. It is provided with two (2) relay outputs that supply 120 Volts to
control lights and signal an alarm. It is also provided with one (1) NTC probe input for temperature measurement. To
ease installation on existing walk-in coolers the unit has been installed in a VBOX pre-wired with an outboard buzzer,
magnetic door switch (MDS), a 9V battery harness, a pigtail harness for the unit power and the light. There is also a five
pin port that allows the user to program the parameter list with a "Hot Key".
Note: The default settings are listed in the back of this manual. They are set for Coolers (Medium
Temp). For Freezers (Low Temp) you MUST Change the ALL and ALU settings. See Section 4.0
We have responded to many requests to make a change in the way the light key operates. It now
overrides the Digital Input to allow a manual OFF prior to the "Lht" being exhausted.
2. GENERAL WARNINGS
2.1
PLEASE READ BEFORE USING THIS PRODUCT
 This manual is part of the product and should be kept close to the instrument for easy and quick
reference.
 The instrument shall not be used for purposes different from those described hereunder. It cannot be used
as a safety device.
 Check the application limits before proceeding.
2.2
SAFETY PRECAUTIONS **READ ME FIRST!**
Check if the supply voltage is correct before connecting the instrument.
Do not expose the back of the instrument to water or moisture: use the controller only within the operating limits
avoiding sudden temperature changes with high atmospheric humidity to prevent the formation of condensation.
Be sure to seal any J-Box with RTV sealant to prevent cold and moisture intrusion.
Warning: disconnect all electrical connections before performing any maintenance operation.
Fit the probe where it is not damaged by the end-user. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor (see address) with a detailed
description of the fault.
Consider the maximum current that can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from each other,
without crossing or intertwining or you may get bad temp readings.
 The box supplied is not suitable for exterior use. If a water tight box is required contact the distributor.
Weiss Instruments,LLC. 905 Waverly Ave. Holtsville , NY 11742 631-207-1200 www.weissinstruments.com
Operating Instructions XWA11V
XWA11V-KIT
dIXEL
(UL SPEC 0873)
V8.8-KIT
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XWA11V and is the answer not in the manual?

Questions and answers

Summary of Contents for dixell XWA11V

  • Page 1 1. GENERAL DESCRIPTION Model XWA11V-KIT, 100x64 mm format, is a microprocessor based light and alarm management controller, suitable for temperature monitoring in a walk-in cooler or freezer. It is provided with two (2) relay outputs that supply 120 Volts to control lights and signal an alarm.
  • Page 2 Operating Instructions XWA11V V8.8-KIT 3. INTERFACE L OW HIGH FRONT PANEL OPERATION In Programming Mode press to select a parameter or to confirm an operation. Press and hold this key for more than 5 seconds to turn the controller OFF. (onF=y) Press and hold this key for more than 1 second to turn the controller back ON.
  • Page 3 Operating Instructions XWA11V V8.8-KIT 3.3 USE OF LEDS Each LED function is described in the following table: MODE Function ALARM signaling The light is on °C Celsius operation °F Fahrenheit operation 4. TEMP ALARMS SETTING 4.1 HOW TO SET THE MIN TEMPERATURE ALARM ...
  • Page 4: Light Management

    With the intorduction of V8.8 it is now possible to overrided the light on time with a press of the light button on the face of the XWA11V. Regardless of mode in which the light had been turned on the Light button will always overide a door switch activation or occupancy sensor input.
  • Page 5: Electrical Connections

    Display will flash when battery runs low. (Battery not included) 9. USE OF THE PROGRAMMING “HOT KEY” The XWA11V units can UPLOAD or DOWNLOAD the parameter list from its own E2 internal memory to the “HOT KEY” and vice versa.
  • Page 6: 11. Technical Data

    Operating Instructions XWA11V V8.8-KIT 10.2 ALARM RECOVERY Probe alarms: “P1” (probe1 faulty), they automatically stop 10seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature° alarms “HA” and “LA” automatically stop as soon as the thermometer temperature returns to normal operating values or when the defrost starts.
  • Page 7 Operating Instructions XWA11V V8.8-KIT 13. AGENCY APPROVALS, LISTINGS AND SUPPORT INFORMATION Weiss Instruments, LLC., 905 Waverly Ave., Holtsville, NY 11742 Phone: (631)207-1200 Fax: (631)207-0900 sales@weissinstruments.com www.weissinstruments.com Weiss Instruments, LLC. 905 Waverly Ave. Holtsville , NY 11742 631-207-1200 www.weissinstruments.com...
  • Page 8 Operating Instructions XWA11V V8.8-KIT 14. DEFAULT PARAMETER MAP LABEL DESCRIPTION VALUE LEVEL RANGE Thermostat probe calibration [-21°F to 21°F] Temperature measurement unit °C - °F Resolution (only for °C) dE - in Display update 0 to 255 (sec.) Off function enabling...
  • Page 9 Operating Instructions XWA11V V8.8-KIT LHt Light timer: (0-255 min) Amount of time the light will stay on after pressing the light switch on the keyboard or after the door is closed. FLH Light Flashing: (0-5 min) The light will “double flash” every 20 seconds during the FLH time period before turning off after the LHt time.

Table of Contents