SKF 234-13163-9 Service Manual

SKF 234-13163-9 Service Manual

Piston detectors with adapters, optionally with cable break protection
Hide thumbs Also See for 234-13163-9:

Advertisement

Piston detectors
with adapters, optionally with cable break protection
Universal Piston Detector
1
2/4
Bipolar Piston Detector
1 (4)
4(1)
Version 04
951-150-032-EN
1
L+
L+
2/4
3
L-
L-
IMPORTANT NOTE!
L+
For use only in combination with SKF lubrication
pumps of series KFAS/KFBS/KFGS in the com-
L-
mercial vehicles and farm machinery.
Service manual
http://www.skf.com/binary/
Further language versions can be found on the SKF homepage.
Weitere Sprachversionen finden Sie auf der SKF-Homepage.
D'autres versions linguistiques disponibles sur le site SKF.
O
h ‡ ¡ ¢
e h
EN
http://www.skf.com/binary/41-286788/951-150-032-DE.pdf
EN
http://www.skf.com/binary/12-286814/951-150-032-EN.pdf
FR
http://www.skf.com/binary/43-286786/951-150-032-FR.pdf
ES
http://www.skf.com/binary/42-286814/951-150-032-ES.pdf
NL
http://www.skf.com/binary/174-286814/951-150-032-NL.pdf
IT
http://www.skf.com/binary/44-286814/951-150-032-IT.pdf
ZH
http://www.skf.com/binary/20-286814/951-150-032-ZH.pdf
FI
http://www.skf.com/binary/154-286814/951-150-032-FI.pdf
EL
http://www.skf.com/binary/175-286814/951-150-032-EL.pdf
YES http://www.skf.com/binary/177-286814/951-150-032-JA.pdf
RU
http://www.skf.com/binary/39-286814/951-150-032-RU.pdf
PL
http://www.skf.com/binary/55-286814/951-150-032-PL.pdf
DE EN FR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 234-13163-9 and is the answer not in the manual?

Questions and answers

Summary of Contents for SKF 234-13163-9

  • Page 1 Universal Piston Detector Further language versions can be found on the SKF homepage. Weitere Sprachversionen finden Sie auf der SKF-Homepage. D‘autres versions linguistiques disponibles sur le site SKF. h ‡ ¡ ¢...
  • Page 2 EU Declaration of Conformity EU Declaration of Conformity in accordance with Directive 2014/30/EU Annex IV The manufacturer, SKF Lubrication Systems Germany GmbH , Walldorf Plant, Heinrich-Hertz-Str. 2-8, DE - 69190 Walldorf, hereby declares conformity of the electrical device Designation: Piston detector Type: Magnetic sensor M..G...
  • Page 3 Conditions. Tel: +49 (0) 6227 33-0 ○ Intentional or gross negligence Fax: +49 (0) 6227 33-259 ○ Use of non-original SKF spare parts Berlin Plant The maximum liability for loss or damage Motzener Strasse 35/37 resulting from the use of our products is...
  • Page 4: Table Of Contents

    Indicates the requirements that must be Wear personal protective gear met for the actions described Overview, functional description (protective clothing) in the following Progressive feeder overview with universal piston detector 234-13163-9 or Pressure injection General notes bipolar piston detector 234-11454-1 Design Hot surfaces 3.2.1 Function...
  • Page 5: Safety Instructions

    1st Safety instructions /2. Delivery and storage 1. Safety instructions 2.1 Storage ○ Putting the products into operation or To convert the piston detector, consult the documentation for the feeder operating them without having read the Storage conditions- See feeder documenta- (lifecycle manual, assembly instructions) in instructions is prohibited.
  • Page 6: Overview, Functional Description

    3. Overview, functional description 3. Overview, functional description 3.1 Progressive feeder overview with universal piston detector 234-13163-9 or bipolar piston detector 234-11454-1 Mounting dimensions, universal and bipolar piston detectors, Fig. 1 VPBM SW 17 SW 12 SW 13 SW 12...
  • Page 7 The universal piston detector ment, 2-wire design or 3-wire design (with When the piston detector is actuated (piston 234-13163-9 and the bipolar piston detec- cable break protection). stroke), a yellow LED lights up and indicates tor 234-11454-1 are position sensors that, The universal piston detector is not suitable correct functioning of the piston detector.
  • Page 8: Bipolar Piston Detector 234-11454-1

    1 in the Universal piston detector and hold a metallic object in front of the PN: 234-13163-9 2 o £ £ ¤ ¥ ¦ o § ¨ © © s  £  ¤ £ ¦ respective national languages (at- ƒ...
  • Page 9: Technical Data

    4. Technical data 4. Technical data 4.1 General technical data General data Designation Dimension drawing Field of application Lubricant feeders Ambient temperature [°C] -40 ..+85 Principle of operation Piston detector/position sensor Material Housing: Stainless steel; plug: PEI Mounting type Mountable flush in associated adapter Tightening torque [Nm] 7 ±0.5...
  • Page 10 4. Technical data Universal Piston Detector Bipolar Piston Detector Universal piston detector Electrical data 3-wire DC PNP Connector pin assignment with cable break Design 2-wire DC PNP/NPN 2-wire DC PNP/NPN protection 3-wire DC PNP Operating voltage 10-36 DC, supply class 2 per cULus Power consumption [mA] <...
  • Page 11: Assembly

    5. Assembly 5. Assembly Assembly drawing, Fig. 2 5.1 Disassembly of the old piston detector (VPB/VPK/PSG1/VP/PSG2/PSG3/SSV/SSVD) 5.2 Assembly of the new piston detector (VPB/VPK/PSG1/VP/PSG2/PSG3) 5.2 Assembly of the new piston detector (SSV/SSVD) PSG1 PSG2 PSG3 SSV D SSVD - 11 - 951-150-032-EN Version 04...
  • Page 12: Assembly Of The New Piston Detector

    5. Assembly 5.1 Disassembly of the old piston detector 5.2 Assembly of the new piston detector see Figures 1 and 2 see Figures 1 and 2 • Disconnect the electrical connection cable (2) from the • Grease the new sealing ring (6) and place old/defective piston detector.
  • Page 13: Conducting Initial Functional Test

    5. Assembly Conducting initial functional test See Figure 2 Avoid uncontrolled tightening of • Attach the adapter cable (9) in a stress- the piston detector, as this could free position. The piston detectors automatically detect cause damage. the clearance between the feeder piston and Maintain tightening torque of •...
  • Page 14: Malfunctions, Causes, And Remedies

    6. Malfunctions, causes, and remedies 6. Malfunctions, causes, and remedies Malfunctions table Malfunction Possible cause Remedy Socket not connected or connected Check plug contacts incorrectly Install socket correctly Signal line is broken Check signal line Piston detected is not installed correctly Check engagement depth of adapter and piston detector, tighten if necessary None Feeder signal...
  • Page 15: Spare Parts

    Adapter sleeves can be changed only on depressurized feeders! Designation Order number Designation Order number Quantity 2-wire or 3-wire connection Universal Piston Detector 234-13163-9 Bipolar piston detector 234-11454-1 2-wire connection for vehicle lubrication VP adapter sleeve 44-0159-2509 VP stopper WVN 501-12x1.5...
  • Page 16 Bearings Lubrication Seals and Bearing Systems Units Services Mechatronics 951-150-032-EN July 2018 Version 04 SKF Lubrication Systems Germany GmbH Walldorf Plant Heinrich-Hertz-Str. 2-8 DE - 69190 Walldorf Tel: +49 (0) 6227 33-0 Fax: +49 (0) 6227 33-259 E-mail: Lubrication-germany@skf.com www.skf.com/lubrication...

This manual is also suitable for:

234-11454-1

Table of Contents

Save PDF