Summary of Contents for Energotech EnergoControl T60-EH

  • Page 1 EnergoControl Touchscreen Thermostat T60-EH and T60-EW User Guide...
  • Page 3: Table Of Contents

    Table of Contents LCD Main Display ..........Overview ............. Mode Selection ........... Getting Started ............ Mode 1 - Thermostat Mode Away Mode ............Optimum Start / Adaptive Start ......Air Humidity ............Hold Mode (Timer Function) ......Holiday Mode ............. Schedule .............
  • Page 4: Lcd Main Display

    LCD Main Display...
  • Page 5: Overview

    Overview Wi-Fi indicator - Displayed when connected to a Wi-Fi network (T60-EW only). Hold: Temperature Hold / Timer Function. Adjusting the optional settings. Day Indicator and Clock. Away: Allows a preset set-back temperature while away from the premises. OPT (Optimum): Displayed ON/OFF of the “Adaptive/Optimum Start”. Air Humidity: - If humidity value less than 30%, the pointer will be in the Red area - If humidity value is between 30% and 60%, the pointer will be in the Green area...
  • Page 6: Mode Selection

    Mode Selection The T60 can either be used as a Thermostat or a Time-clock. Thermostat Mode – Allows time and temperature settings to be made. The thermostat can be fully programmed to a specific temperature during a specific time. The T60 provides three programming options: •...
  • Page 7: Getting Started

    Getting Started This page applies only if you have purchased the Wi-Fi version, T60-EW, of the thermostat Pairing the T60-EW thermostat with the App Use only the 2.4GHz band, if you have an selectable dual-band router. Download the free T60 App from the Apple Store or Google Play Store by searching MyComfort House.
  • Page 8: Mode 1 - Thermostat Mode

    MODE 1 - THERMOSTAT MODE / Operation of Main Display Away Mode The Away Mode is a shortcut button to easily change to a preset temperature when leaving the premises. The range is 7-35°C, default is 7°C. In Away Mode, the T60 will only turn the heating ON if/when the room temperature drop below the set Away Temperature, this is configured in Feature Settings.
  • Page 9: Holiday Mode

    Press the “Hold” and entry in setting interface. Press the Second/Third columns of Hour/Minute, use the icons to set the desired “Hold Time”. Press the first column of “Hold Temp”, use the icons to set the desired Hold Temperature, the temperature range is 5°C - 45°C. Press the icon to save and return to main display, or press the “Cancel ”to delete the setting.
  • Page 10 Press the icon to save and return to main display. Press the “Schedule” on the main display, and enter “Edit” interface. On the edit page, from Monday to Sunday, can be selected to edit. Press “Monday” and enter Monday’s setting interface, Four Time Periods, can be selected.
  • Page 11: Feature Settings

    Feature Settings Language Press the icon and enter Feature Settings. Find the “Language” option, press it and enter setting interface. Select your desired language. Press the icon twice to save and return to main display. Time Zone Selection Press the icon and enter Feature Settings.
  • Page 12: Backlight Setting

    Backlight Setting Ambient Light Dimming: When this function is enabled, the light sensor will detect when to dim the back-light if the ambient light levels drop. If you turn the room lights off, the back-light will dim so the T60 does not light up the room. Press the icon and enter Feature Settings.
  • Page 13: Network Setting

    Lock Pin Options For example, set your personal pin code to 5209 Press the First Column use the icons to set to Press the Second Column use the icons to set to Press the Third Column use the icons to set to Press the Fourth Column use the icons to set to Press the icon...
  • Page 14: Temperature Format

    Temperature Format Press the icon and enter Feature Settings. Find the “Temp Format” option, press it and enter setting interface. There are two options °C / °F. Press the icon in the front of °C °F and it will turn to Press the icon twice to save and return to main display.
  • Page 15: Output Delay

    of the thermostat. The system defaults to 0.5°C, meaning that when the tempera- ture is set to 20°C, the thermostat will start heating at 19.5°C and stop at 20°C. If the default value is 1° degree, start heating at 19°C, stop at 20°C. The switching differential is settable between 0.5°C - 3°C .
  • Page 16: Sensor Selection And Calibration

    Note: The Remote Air Sensor must not be used for controlling electric underfloor heat- ing. Only floor sensors are available or both (Remote Air & Floor Sensor) should be used. If the optional air- or floor sensor is not supplied by Energotech, an 10 kΩ sensor must be used together with the thermostat.
  • Page 17: Humidity Sensor - Calibration

    Humidity Sensor - Calibration This option allows you to calibrate the humidity sensor. You should only calibrate the sensor if the reading differs from the actual air humidity. You can calibrate the sensor with ± 30% in steps of 1% in the following way: Press the icon and enter Feature Settings.
  • Page 18: Optimum Start / Adaptive Start

    Press the icon twice to save and return to main display. Optimum Start / Adaptive Start The function is selected in the main display. Daylight Saving Time (DST) Press the icon and enter Feature Settings. Find the “DST” option, press it and enter the setting interface. Auto DST Options There are three options: European Union /US &...
  • Page 19: Reset To Factory Settings

    Reset To Factory Settings Press the icon and enter Feature Settings. Find the “Reset To Factory Settings” option, press it and enter the setting interface. Press ‘Reset’ for factory settings. The thermostat will automatically restart. Warning! Reset will make you lose the current settings and return to the factory settings.
  • Page 20: Mode 2 - Time Clock

    MODE 2 - TIME CLOCK Setting the Time Clock To program the time clock times, when in time clock only mode, follow these steps. Press “Schedule” on the main display. Press ‘Weekday’ or ‘Weekend’ and enter setting interface. Four time periods, Morning / Day / Evening / Night, can be selected to program. (Each period has ON/OFF icon options) Press the ‘Hour’...
  • Page 21 Press the ‘Minute’ frame and use the icons to set the desired minutes. Press the icon to save and return to the main screen. The remaining boost time, will be displayed at the top of the display. To cancel ‘Boost’, press ‘Boost’ main icon and press cancel. Notes ____________________________________ ____________________________________...
  • Page 23: Technical Specification

    Operating voltage / Power supply 85-230VAC, 50/60Hz Standby power < 1.0W Rated Current / Relay 16A resistive load, 230V Setting range, temperature 5-45°C Floor limitation, temperature range 20-45°C On/Off differential ±0.5°C Humidity sensor, air 0-100% Three programming modes: Weekday/Weekend (5 + 2) - edit/set 4 time periods per day Seven day programming (7) - edit/set 4 time periods per day...
  • Page 24 Energotech AB Firmagatan 5 SE-213 76 Malmö, Sweden Tel: +46 40 866 90 info@energotech.se www.energotech.com For latest updated information please visit our website...