Insurice PF Single 7SI System
SELECTING A LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights of the Insurice PF
Systems are:
• Insurice PF Single - 7SI - 16 lbs (7.26 kg)
• Insurice PF Twin - 7SI - 29 lbs (13.15 kg)
2. The location should allow for:
• Minimum clearance of 2
• Adequate space for "in" and "out" water line connections.
• Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard™ Low Pressure Alarm is
used. See Step 5.
OPERATING SPECIFICATIONS
• For cold water use only.
• Operating Temperature: 35 – 100°F (2 – 38°C)
• Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar), non-shock
• Flow Rate:
System
Insurice PF Single – 7SI
Insurice PF Twin – 7SI
Insurice PF Triple – 7SI
Insurice Quad PF - 7SI
INSTALLATION INSTRUCTIONS
1. Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes. Mount securely. See
Figures 1 – 4 .
2. Shut off power to equipment.
3. Connect outlet port of the Insurice PF System to equipment served. Always use an NSF approved pipe dope or Teflon
tape at all connections. Use a backup wrench on all fittings while connecting to avoid excessive stress on the system
components.
4. Install a manual shut-off valve leading to the system for servicing.
5. Connect minimum 3/8" water line to the Insurice PF Single System inlet. Use a minimum 1/2" for Insurice PF Twin, Triple
and Quad Systems.
6. Connect tubing to flushing valve and run to drain. The cross fitting has a flushing valve installed
on the bottom.
Note: Some municipal plumbing codes and good sanitary practices require an air gap at the
drain termination point.
FILTRATION & PROCESSING SOLUTIONS
7SI INSURICE
®
Insurice PF Twin – 7SI System
" under the cartridge(s) so it can be lowered for removal and replacement.
1
2
Replacement Cartridge
Flow Rate
7SI
3.5 gpm (13.25 Lpm)
7SI
7.0 gpm (26.50 Lpm)
7SI
10.5 gpm (39.75 Lpm) 75,000 gal. (283,906 L)*
7SI
14.0 gpm (53.00 Lpm) 100,000 gal. (378,541 L)*
7SI INSURICE PF SYSTEMS INSTRUCTION & OPERATION GUIDE
PF SYSTEMS
®
Insurice PF Triple – 7SI System
• Insurice PF Triple - 7SI - 37 lbs (16.79 kg)
• Insurice PF Quad - 7SI - 43 lbs (19.50 kg)
Capacity
25,000 gal. (94,635 L)*
50,000 gal. (189,271 L)*
*As tested by Everpure
Insurice PF Quad – 7SI System
®
Air Gap

Advertisement

loading
Need help?

Need help?

Do you have a question about the Insurice PF Single and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Everpure Insurice PF Single

  • Page 1 4. Install a manual shut-off valve leading to the system for servicing. 5. Connect minimum 3/8" water line to the Insurice PF Single System inlet. Use a minimum 1/2" for Insurice PF Twin, Triple and Quad Systems. 6. Connect tubing to flushing valve and run to drain. The cross fitting has a flushing valve installed Air Gap on the bottom.
  • Page 2 (Inside Sump) 11. Open the flushing valve and flush the cartridge(s) by running water through at Figure 1 - Insurice PF Single - 7SI System full force for ten (10) minutes. This will set the filtering media and purge any air and fines, insuring maximum filter life.
  • Page 3 4. Feel head o-ring. If dry, lubricate with high quality silicone lubricant. Everpure Filter Cartridge Change ® 1. Shut off power to equipment. 2. Open flushing valve to relieve 4. Pull cartridge downward and 6. Turn cartridge to right 90° until 8.
  • Page 4: Limited Warranty

    Pentair® Everpure technical service at the phone number listed below. Any part found materially defective within the terms of this warranty will be repaired or replaced (at PFS’s discretion) by your local dealer or Pentair Everpure technical service. You pay only freight from our factory and local dealer charges.

This manual is also suitable for:

Insurice pf twinInsurice pf tripleInsurice pf quad