ELECTRICAL
WIRING
CONNECTIONS
[_.WARNING_
Fire
hazard.
Incorrect
voltage
can cause
a fire or
seriously
damage
the motor
and voids
the warranty.
The supply
voltage
must
be within
± 10% of the motor
nameplate
voltage.
NOTICE:
Dual-voltage
motors
are factory
wired
for 230 volts. If nec-
essary,
reconnect
the motor
for 115 volts,
as shown.
Do not alter
the wiring
in single
voltage
motors.
Install,
ground,
wire,
and maintain
your pump
in compliance
with
the National
Electrical
Code (NEC) or the Canadian
Electrical
Code
(CEC),
as applicable,
and with
all local codes
and ordinances
that
apply.
Consult
your local building
inspector
for code
information.
Motor wires connect here.
-Power supply wires connect here.
230 Volt: Connect 2 hotwires (black and red)
here and cap the white (neutral) wire. it does
not matter which wire goes to which screw.
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connec_the white (neutral) wire
to the other screw. Cap any remaining
• black or red wires.
prevent strain
on the terminal screws.
- Connect the green (or bare copper) ground wire
to the green ground screw.
3187 0398
FIGURE
6 - Pressure
switch wiring
Connection Procedure:
1.
Connect
the ground
wire first as shown
in Figure 9. The ground
wire must
be a solid copper
wire at least as large as the power
supply
wires.
2.
There
must
be a solid metal
connection
between
the pressure
switch
and the motor
for motor
grounding
protection.
If the
pressure
switch
is not connected
to the motor,
connect
the
green
ground
screw
in the switch
to the green
ground
screw
under
the motor
end cover.
Use a solid copper
wire
at least as
large as the power
supply wires.
3.
Connect
the ground
wire to a grounded
lead in a service
panel,
to a metal
underground
water
pipe,
to a metal
well casing
at
least ten feet (3M) long,
or to a ground
electrode
provided
by
the power
company
or the hydro
authority.
4.
Connect
the
power
supply
wires
to the
pressure
switch
as
shown
in Figure
6.
5. Reinstall
the pressure
switch
cover.
TABLE
II - RECOMMENDED
FUSING
AND
WIRING
DATA
Pump Model
390.2514
390.2518
Motor
Horsepower
1/2
Max. Load
Amperes
10.5/5.2
Volts
115/230
115/230
Branch
Delayed Fuse
Rating Amps
15/15
Distance in Feet From Motor to Meter
0to
51 to
101 to
201 to
50
100
200
300
Wire Size
14/14
14/14
10/14
8/14
3/4
12.4/6.2
20/15
12/14
12/14
10/14
8/14