Grounding
Outlet
If outlet is not grounded,
install a copper wire (at least 14
gauge) from the outlet box, as shown in Figure 4, to a metal
cold water pipe. Use ground clamp on pipe.
IMPORTANT:
The cold water pipe you use as a ground
must have metal continuity to electrical ground. If continuity
is interrupted
by plastic, rubber, or other electrical insula-
tors; such as hoses, fittings, washers
or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector
should be jumped (as shown
in Figure 5), with a length of No. 4 wire clamped
securely
at both ends.
Outlet
Box
Figure 4
Bare co per wire to
coldwatPe_r
pipe.
6690194
No, 4
Clamp
Wire
Metal Water
Pipe
Figure 5
Metar
670 01_4
Automatic
Thermal
Overload
Protection
This pump
motor
has a built:m
automatic
thermal
overload
protector.
If the motor
overheats,
the protector
will open
and cut off power
to the motor
before
the heat
damages
it
internally.
The
overload
will reset
automatically
and
the
pump
will restart
after the pump
cools down below
the dan-
ger point.
IA WARNING ]DO NOT attempt
to work on the pump
or
motor
if the overload
seems
to have
tripped.
The
motor
may restart without
warning
at any time. You
could
be injured
and the pump
damaged
if it starts
when
you are working
on it.
DO NOT attempt to repair a sump pump. Take it to SEARS
for service by a qualified technician.
GENERATOR
SIZING
Below
is the Engine-Generator
Watt
rating
required
to
power
this pump
motor.
Any additional
loads, such as lights,
must be added
to the listed load and the generator
sized ac-
cordingly.
Pump
Minimum Watt
Motor HP
Rating of Generator
1/3
2,200
1/2
2,800
SERVICE
General
AWARNING]Risk
of electric
shock.
When
servicing
pump
always
disconnect
power
to electrical
outlet
and
remove
pump
electric
cord
from
outlet.
Inspect
sump
pump
and
system
components
monthly.
Keep
free of debris
and
foreign
objects.
1. If pump
does not operate:
a.
Check
for loose plug at electric
outlet.
b.
Check
for blown
fuses
or tripped
circuit
breakers
at
fuse box/circuit
breaker
box.
c. Be sure nothing interferes with action of float switch.
d. ff a, b, and c above check OK, plug in a light that you
know works, ff it fights, take your pump to SEARS for
service, flit doesn't light, the electrical circuit is faulty;
consult a licensed electrician.
2. Pump starts, but blows
fuses/trips
circuit
breakers:
After
disconnecting
power
to pump,
remove
it from
sump.
Remove
the plate from
the bottom
of the pump
and make sure that the impeller
turns freely. Remove
any
debris
obstructing
impeller.
If pump
still does not oper-
ate correctly,
return
it to your nearest
SEARS Service
Department
for repairs.
3. Pump runs, but does not empty
sump:
a.
Clean pump
intake
screen.
b. Water may be enteO.ng sump
faster than the pump
can
discharge
it.
c.
Be sure vertical
distance
from pump
discharge
outlet
to discharge
pipe outlet
is 18 feet or less for Model
390.303302
(20 feet or less for Model 390.303491).
d. Be sure discharge
pipe is not plugged
or frozen.
LUBRICATION
Motor has been lubricated
at the factory.
It does not require
additional
oil. Bronze
hearing
in volute
housing
is oil im-
pregnated.
It does not require
additional
oil.

Advertisement

loading