Shallow well jet pump

Advertisement

ELECTRICAL
Disconnect
power
before
working
on pump,
motor,
pressure
switch,
or wiring.
Motor
Switch
Settings
If the motor
can operate
at either
115 or 230 volts, it is set
at the factory
to 230 volts. Do not change
motor voltage
setting
if line voltage
is 230 volts, or if you have a single
voltage
motor.
NOTICE:
Never
wire a 115 volt motor
to a 230 volt line.
Dial Type Voltage Selector
Remove
Hotor
End Cover
Figure 4 - Removing
Motor
End Cover
Figure 5 - Voltage Set To 230 Volts, Dial Type
You will need to remove
the motor
end cover
to change
the voltage
setting.
The illustration
above
also shows
the
pressure
switch.
If the power
supply
connection
still
needs
to be made, the pressure
svdtch
cover v/ill need to
be removed.
Your motor terminal board (located under the motor end
cover) should look like the one at right.
To change to I 15 volts:
1. Make sure power
is off.
2. Turn the dial counter-clockwise
until 115 shows
in the
dial window.
3. Reinstall
the Motor end cover
4. Go to Wiring
Connections,
Page 6.
I_,WARNING] Hazardous
voltage.
Can shock,
burn,
or
kill.
Connect
ground
wire
before
connecting
power
supply
wires.
Use the wire
size (including
the ground
wire)
specified
in the wiring
chart.
If possible,
connect
the pump
to a separate
branch
circuit
with
no other
appli-
ances
on it.
[_.WARNING] Explosion
hazard.
Do not ground
to a gas
supply
line.