Download Print this page

Operating Instructions - Webasto 1531 Operating Instructions

Standard timer / combination timer

Advertisement

Available languages

Available languages

Operating Instructions

Standard Timer /
Combination Timer
day of the week
heater "on" indicator temperature
time display
MO
memory
location
2
MO
alarm
2
indicator
time
program
instant
reverse
selection
heating
General
The standard digital timer/combination timer enables you to preset
the start of the heater operation up to 7 days in advance.
It is possible to program 3 different starting times, only one of which
can be activated.
The standard digital timer features a wakeup alarm function. The
combination timer has a temperature controller. The combination
timer can only be used on Air Top 2000 heaters which allow the
temperature to be preselected.
When the ignition switched on, the timer displays the current time
and the day of the week. When the heater is switched on, the display
and the buttons are illuminated.
After the power supply has been connected, all symbols on the
display will flash. The current time and weekday must be set. No
display occurs in TRS vehicles.
Operation
The timer can be operated in that all flashing symbols can be
adjusted by means of the
pressed within 5 seconds, the time displayed will be stored. If the
and
buttons are pressed for more than 2 seconds, the fast time-
setting mode is activated.
If the ignition is switched off while the heater is operating in the
continuous mode, the remaining operating time of 15 minutes is
displayed and the heater continues to operate for this period of time.
Air Top 2000
On heaters equipped with a fault diagnosis system (Air Top 2000 and
Thermo 90
Thermo 90), a number, i.e. the error code, may be flashing on the
display. In this case, please consult your Webasto dealer.
Webasto Thermosysteme GmbH
82131 Stockdorf'Kraillinger Str. 5'Telefon (089)8 57 94-0
Telefax (089) 8 57 94-448'Telex 5 23 647 webas d
selection
combination digital
timer with
temperature
selection only for
Air Top 2000
Standarduhr mit Wecker
forward
and
buttons. If the buttons are not
Manually: by pressing the button
Switching the
Automatically: by programming the heater starting time
heater on
Switching the
Manually: by pressing the button
Automatically: after the programmed operating time has elapsed
heater off
With the heater running: by programming the remaining operating time
Setting time/
Press the
button for more than 2 seconds - time of the day is
flashing - and set the clock using the
day of the
week is flashing - adjust the day of the week.
week
Viewing
With the ignition switched off: press the
the time
Programming
Press the
button - the memory location is flashing - using the
and
buttons set start of the heater operating time. Day of the week
heater starting
is flashing - set the day of the week. By repeatedly pressing the
time
button, memory locations 2 and 3 can be programmed or the time
display mode can be reached.
Recalling/
Repeatedly press the
displayed. To erase the preset time, press the
erasing preset
times until the time of the day is displayed instead of the memory
times
Programming
The heater must be switched off. Press the
operating time is flashing - and set the desired operating time (10 to
duration of
120 minutes) using the
operating time
Setting the
Set the desired remaining operating time (1 to 120 minutes) using the
remaining
and
buttons. The remaining operating time refers to the time
the heater still continues to remain in operation. It can only be
operating time
changed while the heater is in operation and the ignition switched off.
Setting the
A wakeup time can only be programmed on the standard digital
timer. The wakeup time is not bound to a specific day of the week.
wakeup time
Repeatedly press the
the display. Set the desired wakeup time using the
buttons.The alarm clock turns off after 5 minutes or when one of the
buttons is pressed.
Recalling/
Repeatedly press the
the display - read off wakeup time. To erase the wakeup time: press
erasing the
the
button until the bell symbol
wakeup time
display.
Remote control
Possible by means of an optional external "instant heating" button
Vehicles
On TRS vehicles it is not possible to program a preset starting time.
The remaining time is shown on the display while the heater is in
with TRS
operation. The clock can be set. The alarm clock function can be
equipment
programmed on the standard digital timer.
(continuous heating mode)
and
buttons. Day of the
button
button until the desired memory location is
button several
button for 3 seconds -
and
buttons.
button until the bell symbol
appears on
and
button until the bell symbol
appears on
is no longer visible on the