4) COMMISSIONING THE HEATER ........................... 11 5) TROUBLESHOOTING ............................13 6) PERIODIC MAINTENANCE ............................ 14 7) PART NUMBERS FOR FITTINGS, AERATORS AND AERATOR ADAPTORS ............. 15 8) REPAIR PARTS FOR ACCUMIX II UNITS ........................ 15 Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
SAVE THESE INSTRUCTIONS GENERAL The Eemax, Inc.™ AccuMix II heater is specifically designed to take in cold water and heat it to temperatures suitable for handwashing and other mild temperature uses up to a factory preset of 105°F. The unit employs a complex algorithm that actively manages power application to real-time system demand.
Make sure to leave a minimum of 8 inches service Remove the cover and fasten to the wall using the clearance at the end OPPOSITE the fittings. four mounting holes at each corner of the back plate. Replace the cover. Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
DAMAGE TO THE HEATER WILL RESULT. DOING THIS WILL VOID THE WARRANTY! Eemax strongly recommends that the heater be supplied directly from the main cold water trunk line when possible. This helps to avoid a potential water flow interruption to the heater which could lead to a failure of the heating element.
Page 7
Check the system for water leaks at all plumbing connections. If a leak is present at the compression fitting, slowly tighten compression nut until it stops – do not overtighten. Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
Page 8
Close the faucet and install the aerator (if supplied). Failure to install aerator (if supplied) will result in lower- than-expected heater performance. Model # of Aerators AM004120T AM005240T AM007240T AM010240T AM012240T AM004277T AM008277T AM010277T Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
AM010277T 10.0 Power cable entry to the heater should be made through one of the knock-out holes located on the back plate or top/bottom ends of the unit. Use the appropriate strain relief fitting. Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
Page 10
4. To switch between silent and non- silent operation place the jumper on the control board in position “D”. Leave the breaker in the “OFF” position. Proceed to the next section: COMMISSIONING THE HEATER Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
The heater is commissioned at this point. Faucet can be turned off and used as needed. Note: the temperature display will turn off after 5 minutes of inactivity. Display turns on when water flows through heater. Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
Page 12
Congratulations! Your Eemax tankless electric water heater is fully installed and ready for use! MAXIMUM TEMPERATURE RISE AT SPECIFIED FLOW RATE, °F 240VAC heaters used at 208VAC Model AM004120T AM005240T AM007240T AM010240T AM012240T AM004277T AM008277T AM010277T *The heaters’ actual temperature rises are limited by their thermostatic controls.
- unit keeps running at disconnected reduced performance Outlet (difficulties maintaining thermistor setpoint temperature failure due to inlet voltage fluctuations) - inlet temperature is too low - unit shuts down* Freeze (below 35°F) warning - inlet thermistor failure Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
If you need any assistance from our Technical Service Department, make sure you can identify this water heater by having the model no:____________________ and serial number:_____________________. 203-267-7890 800-543-6163. Call or toll free: Eemax Inc., 400 Captain Neville Drive, Waterbury, CT 06705 Tel: 800-543-6163, 203-267-7890, Fax: 203-267-7975, email: support@eemaxinc.com Downloaded from https://gadgetsgo.com/Eemax-Accumix-II-277V-tankless-commercial-sinks.html Authorized Eemax Distributor...
Need help?
Do you have a question about the AccuMix II and is the answer not in the manual?
Questions and answers