Download Print this page
Chauvin Arnoux C.A 861 User Manual
Chauvin Arnoux C.A 861 User Manual

Chauvin Arnoux C.A 861 User Manual

Hand-held k-type sensor thermometers
Hide thumbs Also See for C.A 861:

Advertisement

Quick Links

Thermomètres de poche couple K
Hand-held K-type sensor thermometers
Taschenthermometer mit K-Thermoelement
Termometro tascabile coppia K
Termómetro de bolsillo par K
F R A N Ç A I S
E N G L I S H
D E U T S C H
I T A L I A N O
E S P A N O L
Notice de fonctionnement
User's manual
Bedienungsanleitung
Libretto d'Istruzioni
Manual de Instrucciones
1
C.A 861
C.A 863

Advertisement

loading

Summary of Contents for Chauvin Arnoux C.A 861

  • Page 1 C.A 861 Thermomètres de poche couple K Hand-held K-type sensor thermometers Taschenthermometer mit K-Thermoelement C.A 863 Termometro tascabile coppia K Termómetro de bolsillo par K F R A N Ç A I S Notice de fonctionnement E N G L I S H...
  • Page 2: Safety Precautions

    This instrument, in overvoltage category III, meets with the strict reliability and environmental requisites that apply to fixed industrial and domestic installations (see IEC 664-1 ed 92). C.A 861 or C.A 863 hand-held Thank you for purchasing a thermometer To get the best service from this instrument: n read this user’s manual carefully,...
  • Page 3 SENSORS ..............13 MAINTENANCE ............15 TO ORDER ..............15 ATTACHMENT ............. 37 1. PRESENTATION The C.A 861 and C.A 863 are high precision hand-held temperature measurement instruments, lightweight, with digital display, and easy-to-use with interchangeable K-type thermocouples. 2. DESCRIPTION See §...
  • Page 4 C.A 861 : Command push button for max. temperature value C.A 863 : Scroll-down menu for going from T1 to T2 and then ∆T. Shock-proof moulded surround 3. USE Procedure 1. Connect one or two sensors 2. Switch on the thermometer: select one or two measurement...
  • Page 5: Specifications

    4. SPECIFICATIONS The temperature range depends upon the K type thermocouple chosen (see section 5): - C.A 861 : -40 to +1350°C (-40 to 2000°F) -40 to +200°C (-40 to +392°F) with K type thermocouple supplied as standard. - C.A 863 : -50 to +1300°C (-58 to 2000°F) -50 to +200°C (-58 to 392°F) with the K type...
  • Page 6 5. SENSORS The following K-type thermocouple sensors can be used with thermometers C.A 861 and C.A 863. Sensors with grips and extendible spiral leads Model Reference Measurement Response Dimensions range time (mm) SK 11 Needle P03.6529.17 -50...+600°C 12 s Ø 3 - L = 130 For penetration of viscous thick substances.
  • Page 7 1 s/contact SK 6 P03.6529.06 -50...+285°C Ø 1 - L = 1000 3 s in Flexible ambient air Recommended for difficult-to-get-at measurement points SK 7 Air P03.6529.07 -50...+250°C Ø 5 - L = 150 For ambient air temperature measurement. Thermocouple protected by 8.5 mm Ø...
  • Page 8: Maintenance

    7. TO ORDER C.A 861 .............. P01.6501.01.Z C.A 863 .............. P01.6502.01.Z Comes with shock-proof surround, a 9 V battery, a sensor (C.A 861) or two sensors (C.A 863) and this user’s manual. Spares: 9 V battery ............P01.1007.32 Accessories :...