13. Check burner gasket and cylinder assembly for damage
Check the burner gasket
replace if necessay. Replace the burner cylinder assembly if damaged.
14. Check and adjust ignition and ionization electrodes
1. Check ignition and ionization
electrode
for wear and
contamination.
2. Clean electrodes with a small brush
or emory paper.
3. Check clearances. If clearances are
not satisfactory or the electrodes are
damaged, replace electrode block
and gasket and align. Tighten
fastening screws for the electrodes
to a torque of 1.8 lb.ft. / 2.5 Nm
using a calibrated torque wrench.
Legend
Ignition and ionization electrodes
Grounding rod
Initial Start-up, Inspection and Maintenance
and burner cylinder assembly
1. Remove electrode block
2. Loosen the three Torx screws and
remove the thermal insulation ring
.
3. Loosen the four Torx screws and
remove burner cylinder assembly
and assembly gasket
4. Fit and secure new burner cylinder
assembly
gasket
Tighten to a torque of 2.5 lb.ft. /
3.5 Nm using a calibrated torque
wrench.
5. Reinstall thermal insulation ring
6. Reinstall electrode block
Tighten to a torque of 1.8 lb.ft. /
2.5 Nm using a calibrated torque
wrench.