SECTION 3—OPERATING PROCEDURES & TROUBLESHOOTING
Detect-A-Finger
Drop Probe Device-Welder
®
Troubleshooting
Resistant Measurement Troubleshooting
TERMINAL
From
To
a
b
b
a
a
c
c
a
d
b
b
d
d
c
c
d
Power off with components not connected.
Bridge Rectifier, Terminal Identification
Readings may vary slightly from meter to meter. However, the
trend established between infinity (∞ ) and the lower readings
must remain consistent throughout the test. Any unusual reading
means the bridge rectifier is defective and must be replaced.
Transformer: Primary - 20 Ohms approx.
Secondary - 2 Ohms approx.
Rotary Solenoid - Resistance 7.72 Ohms.
AC solenoid air valves of the type usually supplied by Rockford
Systems, LLC have approximately
100 Ohms DC resistance.
18
RESISTANCE
OHMS
700
700
700
700
(a)
(b)
(c)
(d)
(-DC)
AC
AC
(+DC)
Rockford Systems, LLC
Call 1-800-922-7533