Appendix A. Model 8032-27 And Load Cell Wiring - Geokon 4999 Instruction Manual

Terminal box
Table of Contents

Advertisement

APPENDIX A. MODEL 8032-27 AND LOAD CELL WIRING

Connect the "common" VW- conductor from the load cell to the 8032-27 by lifting up on
the orange tab located on the opposite side of the six black conductors, inserting the
common conductor fully into the 8032-27 (Figure 1), and then pushing down on the
orange tab until it snaps into place. Refer to Table 1 to identify which conductor carries
the common VW- signal.
10 pin Bendix
PT06A-12-10P
Function
H
Common
*
White's black and Green wires are switched on Geokon 3 gage VW load cells prior to serial number 3313.
The following wiring charts detail the connections between the load cell and 8032-27
with the terminal board:
Figure 1 - Model 8032-27 Jumper Wire Assembly
3 Gage VW Load Cell,
Purple Cable
White's Black*
Table 1 -Common Conductor Chart
4999-11-4S
Terminal
Vibrating Wire
Board
with Thermistor
1H
VW Sensor #1
1L
2H
2L
SHIELD
Shield Drain Wire
3H
VW Sensor #2
3L
4H
4L
SHIELD
5H
VW Sensor #3
5L
6H
6L
SHIELD
7H
VW Sensor #4
7L
8H
8L
SHIELD
4 Gage VW Load Cell,
Purple Cable
Green
8032-27
Thermistor
Thermistor
8032-27
-
-
-
8032-27
-
-
-
8032-7
-
-
-
10
6 Gage VW Load Cell,
Orange Cable
Blue

Advertisement