ASSEMBLY INSTRUCTIONS
Tools Needed for Assembly
* pipethread sealant (not incJuded)
, an a, c lJustable wrench for attaching the pressure
regulator
" a _t_0, s ocket or open end wrench for attaching the
wheels and hose adaptan
" a 7/1_open and wrench for attaching the air pressure
gauges
, a _e °'he, v.Re'i" f or Installing the plug in the regulal_
, a %" open end wrenchto tighten handlescrews
"s #2 philtipe screwdriver for attaching the control
cover
installing Wheels, Handle, Rubber Foot Strip
i
WARNIN_
!
THE WHEELS AND HANDLE OO NOT PRO-
VIDE ADEQUATE CLEARANCE, $TABJLITY
OR SUPPORT FOR PULLING THE UNIT UP
AND DOWN STAIRS OR STEPS, THE UN[T
MUST I_ELtFT]_D, OR PUSHED UP A RAMP.
1. Dipthe handle grip Insoapywater and sttdeintoposi-
tionas shownon photoon page 6 or page 12.
2, Attachthe handleto the insideofthecompressor sad-
diebyp_jshtng the handle In,unllithe slotin thehandle
engageswith the labs in the saddle, Pufithe handle
bsckar<l installthe two s<z_ws,one on each side of
the _e_ldte.Tighten securely,
ittory be necemury to brace or support one
enU of the outfit when attaching the wheels
end the r_Jbber foot _trlp, b ecause the air
compressor will have a tenden=y to tip.
3- Rsmove the protectivepaper strip frOmth_ adhesive
backed rubber footstrip,Attachthe rubberfootstrip to
the bottom of 1he airtitnk leg. Press firmlyinto place°
4. Attach one wheel to each side of the air ¢omp_ssor.
Use one shoulder bott and one nut for each wheel,
Tighten securely.
Installing Regulator
Use a small amountof, pipe thread sealant on aJipipe
thread joints.
Install the regulatoron 1heend of lhe manifold using the
short pipe nipple. The arrow on the bottom ol the
regulatOr must poi_ away from the manifold in order fo_
theregulatorto functionproperly,
_nstali the adapter and plugIn the regulator,, The plug is
supplied with the regulator, I nstallthe rear cover and the
gauges at the same time, See diagram below,
R_ULATED
PRESSURE
GAUG_
TANK
PRESSURE
GAUGP-
tnstallthe control_over. Fasten It to the manifoldusing
the phillipsscrew. Installthe plasticmounting ring tothe
regulatorto fastenthe top ofthe contmtcover,See photo
on page 6.
INSTALLATION AND BREAK-IN PROCEDURES
Locationof the Air Compressor
Loca4e the air compressorin a ctean,dry end welJventi-
latecl area. The air filler must be kept clear o'l obstruc.
tlons which could reduce air delivery of the air
compressor. T he air compressorshould be locatedat
least 12' away'from the wail or other obstructionsthat
wl!linterfere withtheftow of air. The air compressorhead
and shroudare designed to al!ow for propercooling., I f
humidity Is high a _ears air filter can be installed iD
remove excessive moisture. Follow the instructions
packaged with the air filter for proper installation,
Lubrication a nd Oil
Thtsunit n_eas no adcllttonal lubrication or otling
Extension Cords
Use extre,air hose insteaxJ Of _n extensioncordto avoid
voltagedrop and power loss to the motor,
tf an axlet_slon cordmust t_ us'_, be sum it is:
. a 3-wire ext_._ion cord that h_ a _-,blade grounding
pll_, end !_3-_lotreceptacletigat wl!laccepttheplugon
the product,
. t_ good condition_
• no longerthan _50 f_t.
.12 gtlUge (AWG) or larger. (Wire size increases as
gauge number _lecreaseso10 AWG and 8 AWG may
atso l_e used, OO NOT USt_ t4 or 16AWG_)