Wiring Diagram; Troubleshooting Guide; Exploded View - Craftsman CMXEHAP60VGFA Instruction Manual

Propane forced air heater
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
For assistance with your product, visit our website at www.craftsman.com for a list of service centers, or call CRAFTSMAN
at 1-888-331-4569.
PROBLEM
Fan does not turn when
electricity is connected.
Heater will not fire (ignite).
Heater stops running
by itself.
6

WIRING DIAGRAM

TROUBLESHOOTING GUIDE

BE SURE TO FOLLOW SAFETY RULES AND INSTRUCTIONS
POSSIBLE CAUSE
1. No electric power to heater.
2. Blades of fan in contact with heater
housing.
3. Fan blades bent.
4. Fan motor defective.
1 . No spark at module.
2 . Incorrect spark gap.
3 . Corroded electrode.
1 . Temperature inside heater is too high,
causing thermal switch to shut down
operation.
2 . Damaged control valve.
3 . Dust or debris accumulated
in heater.

EXPLODED VIEW

4
5
7
8
6
1 . Check current at outlet. If voltage is correct, inspect extension and power
cords for cuts, frays or breaks
2 . Check housing for damage. Be sure there are no dents in the housing
obstructing the fan.
3 . Straighten all fan blades.
4 . Replace motor assembly.
1 . Inspect module wire. Re-attach or tighten if loose. Inspect spark module
and replace if necessary. Inspect all other electrical components.
2 . Set plug gap to 0.16" (4 mm).
3 . Replace spark plug
(multi-bracket assembly).
1 . If the heater input or output is restricted, the inside temperature can
become too hot. Keep the areas in front and behind heater clear of
obstructions.
2 . Replace control valve.
3 . Clean inside of heater.
9
18
15
1
21
2
SOLUTION
10
11
13
14
12
20
19
17
22
16
3
23

Hide quick links: