1. INTRODUCTION DINB100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like: - making almost impossible to make fake copy of the users fingers...
1 Administrator and 1 Installer Finger Backlight ON/OFF: Buzzer ON/OFF: Firmware upgrade: via RS485 converter and windows application Current Consumption: 100 mA max. DINB100-SA v2 Power Supply: 9-14 V DC Indication: Tricolor Status LED IP Factor: IP40 Storage/Operating Temperature : -20°C to +50°C...
Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual. Pairing DINB100-SA with DINRTT 12 VDC 1. Close the Jumper. DINRTT beeps continuously and DINB100-SA v2 DINRTT the red led blinks. 2. Open the Jumper 3.
10. ADMINISTRATOR PROGRAMMING Use point fingers as Administrator and Installer. You can use the other fingers as access fingers. Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual. ADD Finger Relay 1 (Finger that will activate relay 1) Action Finger...
DELETE Finger Action Finger Backlight Buzzer Sound Swipe Admin Finger 4 times short beep slow blinking Wait 5 seconds (until fast blinking) short beep Swipe User Finger short + long beep fast blinking Present card/tag 1 time fast blinking short + long beep DELETE ALL Fingers and Cards Action Finger...
11. INSTALLER PROGRAMMING Set Relay 1 Time Action Finger Backlight Buzzer Sound Swipe Installer Finger 1 time short beep slow blinking Wait 5 seconds (until fast blinking) short beep Swipe the INSTALLER Finger beeps on 1 second fast blinking and start counting seconds Swipe the INSTALLER Finger to stop or wait 30 seconds to fast blinking...
12. ADMINISTRATOR PROGRAMMING BY KEYPAD Programming by keypad can be done only if the DINB100-SA V2 reader is connected to keypad DINPAD-M as shown in the pictures bellow. The connection is done by the cable provided with the biometric reader. Once connected, the keypad must be put in slave mode.
Page 13
ADMINISTRATOR PROGRAMMING BY KEYPAD Note: Entering this menu is done by ENTER ADMIN CODE default: 1234+A admin PIN Code. You can not enter with Admin Finger. MENU Press 0A to exit the Menu DELETE ENROLL ENROLL DELETE Admin Finger Installer Finger User User or PIN Code...
13. INSTALLER PROGRAMMING BY KEYPAD Note: Entering this menu is done by ENTER INSTALLER CODE installer PIN Code. You can not enter default: 5678+A with Installer Finger. MENU Press 0A to exit the Menu Buzzer Set Relay 1 Set Relay 2 Backlight ON/OFF TIME...
Page 16
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012 www.xprgroup.com...