Sanyo VCC-WB4000 Instruction Manual page 31

Network camera day/night
Table of Contents

Advertisement

L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
B/W Mode Settings
1
Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to "B/W".
2
Set "AGC Gain" to "+12 dB" (example).
3
Click the [SET] button.
This completes the B/W mode settings.
Monitoring will switch to black & white
according to the set conditions.
TIMER Mode Settings
Example: To set monitoring to black & white
between 20:00 p.m. and 4.00 a.m.
1
Click the [DETAIL] button in the
1,2
DAY/NIGHT field and set MODE to
"TIMER".
2
Set "AGC Gain" to "+12 dB" (example).
3
Set "ALARM OUT" to "NO" (example).
A signal can be output from the ALARM OUT
terminal when monitoring switches to black &
white. (An IR lamp can be connected so that
it illuminates at such times.)
4
Set "BURST" to "OFF" (example).
5
Change the TIMER ON setting to "20:00"
and the OFF setting to "04:00".
6
Click the [SET] button.
This completes the TIMER mode settings.
Monitoring will switch from color to black &
white during the set time period. At other
times, monitoring will be in color.
– 30 –
1,2,3
4
5
English

Advertisement

Table of Contents
loading

Table of Contents